MC10EL04, MC100EL04
www.onsemi.com
4
Table 6. 100EL SERIES NECL DC CHARACTERISTICS (V
CC
= 0.0 V; V
EE
= −5.0 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 14 17 14 17 16 20 mA
V
OH
Output HIGH Voltage (Note 2) −1085 −1005 −880 −1025 −955 −880 −1025 −955 −880 mV
V
OL
Output LOW Voltage (Note 2) −1830 −1695 −1555 −1810 −1705 −1620 −1810 −1705 −1620 mV
V
IH
Input HIGH Voltage −1165 −880 −1165 −880 −1165 −880 mV
V
IL
Input LOW Voltage −1810 −1475 −1810 −1475 −1810 −1475 mV
I
IH
Input HIGH Current
D0
D1
250
150
250
150
250
150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.8 V / −0.5 V.
2. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.
Table 7. AC CHARACTERISTICS (V
CC
= 5.0 V; V
EE
= 0.0 V or V
CC
= 0.0 V; V
EE
= −5.0 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
f
max
Maximum Toggle Frequency TBD TBD TBD GHz
t
PLH
t
PHL
Propagation Delay to
Output
70 235 410 130 240 370 155 265 395 ps
t
JITTER
Cycle-to-Cycle Jitter TBD TBD TBD ps
t
r
t
f
Output Rise/Fall Times Q (20%−80%) 100 225 350 100 225 350 100 225 350 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. 10 Series: V
EE
can vary +0.25 V / −0.5 V for +25°C and +85°C. or V
EE
can vary +0.06 V / −0.5 V for −40°C.
100 Series: V