PA-N (APAN3)
–2–
ASCTB368E 201604-T
RATING
1. Coil data
Note: *Pulse drive (JIS C 5442)
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Operating frequency of 5 A 250 V AC is 6 times/min. (ON : OFF = 1 s : 9 s)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
3 V DC
70%V or less of
nominal voltage*
(Initial)
5%V or more of
nominal voltage*
(Initial)
36.7 mA 82 Ω
110mW
120%V of
nominal voltage
4.5 V DC 24.4 mA 184 Ω
5 V DC 22.0 mA 227 Ω
6 V DC 18.3 mA 327 Ω
9 V DC 12.2 mA 736 Ω
12 V DC 9.2 mA 1,309 Ω
18 V DC 6.1 mA 2,945 Ω
24 V DC 4.6 mA 5,236 Ω
Characteristics Item Specifications
Contact
Arrangement 1 Form A (Bifurcated)
Contact resistance (Initial) Max. 30 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi type + Au
Rating
Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load) 1,250 VA, 150 W
Max. switching voltage 250 V (AC), 110 V (DC) (0.4 A)
Max. switching current 5 A (AC, DC)
Nominal operating power 110 mW
Min. switching capacity (Reference value)*
1
1 mA 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 3,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown voltage (Initial)
(Between contacts and coil)*
2
6,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 10 ms (excluding contact bounce time)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 5 ms (excluding contact bounce time and without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 147 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 3.5 mm
Expected life
Mechanical Min. 2×10
7
(at 180 times/min.)
Electrical
Min. 10
5
(3 A 250 V AC, 30 V DC, resistive load)
Min. 5×10
4
(5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)*
4
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to 90°C –40°F to 194°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)*
4
Unit weight Approx. 3 g .15 oz