MLX90242ESE-GAA-000-RE

MLX90242
Linear Hall Effect Sensor
3901090242 Page 4 of 10 Data Sheet
Rev. 027 Feb/12
3. Glossary of Terms
- Gauss, Tesla: Two units to quantify a magnetic flux density. Conversion: 1 mT = 10 Gauss
- Voq: Quiescent output voltage. Output voltage for B = 0.
4. Absolute Maximum Ratings
Supply Voltage (Over Voltage), V
DD
7
.0
V
Output Current
Short to Vdd
5
mA
Output Current
Short to Vss
0.5 mA
Output Pin Short to Vss Pin
Infinite
Output Over Voltage
8 V
Operating Temperature Range
, T
A
-
40°C to 150°C
Storage Temperature Range, T
S
-
55°C to 150°C
Maximun Junction Temp, T
J
1
70
°C
Magnetic Flux Density
Infinite
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
MLX90242
Linear Hall Effect Sensor
3901090242 Page 5 of 10 Data Sheet
Rev. 027 Feb/12
5.
MLX90242 Electrical Specifications
DC Operating Parameters. L: T
A
= -40 to 150°C, E: T
A
= -40 to 85°C
V
DD
= 5.0V (Unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max
Units
Supply Voltage V
DD
Operating 4.5 5.0 5.5 V
Supply Current I
DD
B = 0, V
DD
= 5V, I
OUT
= 0 1.8 2.5 4.5 mA
Output Current I
OUT
V
DD
= 5V
Pull-up = 5 kΩ, Pull-down = 50 kΩ
-1.0 - 0.1 mA
Quiescent Output Voltage V
OQ
B = 0, TA = 25°C 2.4 2.5 2.6 V
Output Voltage V
OH
V
DD
= 5V, I
OUT
= -1.0 mA 4.75 V
Output Voltage V
OL
V
DD
= 5V, I
OUT
= 0.1 mA 0.25 V
Response Time tr
Vdd=5V,Vout from Voq to V
OH
/V
OL
without load
400 800 µS
Noise (RMS) 5 10 mV
Output Resistance R
OUT
20
Linearity Error Le 0.5
%Vdd
6.
MLX90242 Magnetic Specifications
V
DD
= 5.0V (Unless otherwise specified)
Parameter Symbol
MLX90242
LUA-GAA-000
MLX90242
ESE-GDA-000
MLX90242
ESE-GAA-000
Min Typ Max Min Typ Max Min Typ Max
Thermal Voq Drift
(1)
(mV)
Τ
V
OQ
-25 25 ±25
(2)
±25
(2)
Sensitivity, T
A
= 25° C
(mV/mT)
S 33.2 39.0 44.9 11.5 15 17.3 33.2 39.0 44.9
TC of Sensitivity
(ppm/°C)
TC
S
430 680 930 680
(2)
)
680
(2)
(1) B = 0 Gauss
(2) For TSOT package, TC of Sensitivity and Thermal Voq Drift are not fully tested and therefore cannot be specified.
Characterization and statistic data can be provided by Melexis upon request.
MLX90242
Linear Hall Effect Sensor
3901090242 Page 6 of 10 Data Sheet
Rev. 027 Feb/12
7. Applications Information
C1 and C2 values can be trimmed to satisfied EMC requirements according to the environment (PCB,
connectors,...).
The output rise time is affected for large capacitor C2, depending of the couple R1;C2.
Recommended Wiring
C1 = 10nF
C2 = 2.5nF
MLX
90242
1
2
3
V
OUT
V
DD
R1 = 10 k

MLX90242ESE-GAA-000-RE

Mfr. #:
Manufacturer:
Melexis
Description:
Board Mount Hall Effect / Magnetic Sensors Linear Hall ICs - Fixed Programmed (Ratiometric analog output)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: