GP2Y0A51SK0F

GP2Y0A51SK0F
4
Sheet No.: OP13007EN
Supplements
Example of output distance characteristics
GP2Y0A51SK0F
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
2.80
3.00
3.20
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Distance to reflective object [cm]
Analog voltage output [V]
White paper (Reflectance ratio 90%)
GP2Y0A51SK0F
5
Sheet No.: OP13007EN
This product shall not contain the following materials.
Also, the following materials shall not be used in the production process for this product.
Materials for ODS : CFC
S
, Halon, Carbon tetrachloride 1.1.1-Trichloroethane (Methyl chloroform)
Product mass : Approx. 2.7g (TYP)
This product does not contain the chemical materials regulated by RoHS directive.
(Except for the NOT regulated by RoHS directive.)
Specified brominated flame retardants
Specified brominated flame retardants (PBB and PBDE) are not used in this device at all.
Compliance with each regulation
1) The RoHS directive(2002/95/EC)
This product complies with the RoHS directive(2002/95/EC) .
Object substances: mercury, lead (except for lead in high melting temperature type solders
*1
and glass of
electronic components), cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated
diphenyl ethers (PBDE)
*1
i.e. tin-lead solder alloys containing more than 85% lead
2) Content of six substances specified in Management Methods for Control of Pollution Caused by Electronic
Information Products Regulation (Chinese : 子信息染控制管理).
Category
Toxic and hazardous substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr
6+
)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Distance Measuring
Sensor
: indicates that the content of the toxic and hazardous substance in all the homogeneous materials of the part is
below the concentration limit requirement as described in SJ/T 11363-2006 standard .
: indicates that the content of the toxic and hazardous substance in at least one homogeneous material of the
part exceeds the concentration limit requirement as described in SJ/T 11363-2006 standard.
Lead in high melting temperature type solders (i.e. tin-lead solder alloys containing more than 85% lead) and
glass of electronic components (designated by “” in the above table) are exempt from the RoHS directive
(2002/95/EC), because there is no effective way to eliminate or substitute them by present scientific technology.
GP2Y0A51SK0F
6
Sheet No.: OP13007EN
Notes
[Advice for the optics]
Lens of this device shall be kept cleanly. There are cases that dust, water or oil and so on deteriorate the
characteristics of this device. Please consider in actual application.
In case that protection is set in front of the emitter and detector portion, the protection cover which has the most
efficient transmittance at the emitting wavelength range of LED for this product (λ=870nm±70nm), shall be
recommended to use. The face and back of protection cover should be mirror polishing. Also, as there are cases
that the characteristics may not be satisfied with according to the distance between the protection cover and this
product or the thickness of the protection cover, please use this product after confirming the operation sufficiently
in actual application.
[Advice for the characteristics]
In case that there is an object near to light exits of the sensor between the sensor and the detected object, please use
this device after confirming sufficiently what the characteristics of this sensor do not change by the object.
When the detector surface receive direct light from the sun, tungsten lamp and so on, there are cases that it can not
measure the distance exactly. Please consider the design that the detector does not receive direct light from such
light source.
Distance between sensor and mirror reflector can not measure exactly.
In case that reflective object has boundary line clearly, there is cases that distance can not measure exactly.
At that time, if direction of boundary line and the line between emitter center and detector center parallels,
it is possible to decrease deviation of measuring distance.
(Incorrect) (Correct)
In order to decrease measuring error by moving direction of object, we recommend to mount the sensor like
below drawing.
(Incorrect) (Correct)
(Moving direction) (Moving direction)
In order to stabilize power supply line, we recommend to connect a by-pass capacitor of 10μF or more between
Vcc and GND near this product.
[Notes on handling]
●Please don’t do washing. Washing may deteriorate the characteristics of optical system and so on.
Please confirm resistance to chemicals under the actual usage since this product has not been designed against for
washing.
There are some possibilities that the sensor inside the case package with lens may be exposed to the excessive
mechanical force. Please be careful not to cause any excessive pressure on the case package with lens and also on the
sensors PCB at the assembly and inserting of the set.

GP2Y0A51SK0F

Mfr. #:
Manufacturer:
Description:
SENSOR OPTICAL 2-15CM ANALOG
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet