Switching spark gap B88069X0680T502
SSG with lead wires CAS02X-068
KB AB E / KB AB PM Issue 05 / 2007-11-22
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Extremely long life time
Stable performance over life
Insensitive performance against variations in
temperature
Low switching losses
Very short breakdown time
High reliability by robust design
RoHS compatible
Ignition circuits
Electrical specifications
DC spark-over voltage
1) 2)
200 ... 255
V
Initial values
Ignition time t
I
after 150 hours in darkness
3)
95 99.9 100 %
at –20 °C
at +25; 125 °C
≤ 4
≤ 2
≤ 5
≤ 3
≤ 7
≤ 4
s
s
Electrical life time
Maximum increase of DC spark-over voltage 25 V
Switching operations at +25; 125 °C
Switching frequency 10 … 25 Hz
Switching frequency < 10Hz
2 000 000
4 000 000
Ignitions
Ignitions
Test circuit parameters
Open circuit voltage V
0'
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current I
P
230
15
2.2
10
~ 300
V
ac
kΩ
µF
µH
A
Insulation resistance at 100 V
dc
> 0.1
GΩ
Capacitance at 1 MHz < 2 pF
Weight ~ 1.5 g
Operation and storage temperature -20 ... +125 °C
Climatic category (IEC 60068-1) 20/ 125/ 21
Marking, red positive
CS 230 YYMM O
CS - Series
230 - Nominal voltage
YY - Year of production
MM - Month of production
O - Non radioactive