www.vishay.com
2
Document Number 83649
Rev. 1.6, 20-Apr-07
Vishay Semiconductors
ILD256T
For technical support, please contact: optocoupler.answers@vishay.com
Note:
1)
T
amb
= 25 °C, unless otherwise specified.
Stresses in excess of the absolute Maximum Ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute Maximum
Rating for extended periods of the time can adversely affect reliability.
Note:
1)
T
amb
= 25 °C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
Note:
1)
As per IEC60747-5-2, §7.4.3.8.1, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with the
safety ratings shall be ensured by means of prodective circuits.
COUPLER
Isolation voltage, input to output t = 1.0 s V
ISO
4000
V
RMS
Total package dissipation
(LED + detector)
P
tot
300 mW
Derate linearly from 25 °C 4.0 mW/°C
Storage temperature T
stg
- 55 to + 150 °C
Operating temperature T
amb
- 55 to + 100 °C
Soldering temperature at 260 °C T
sld
10 sec.
ELECTRICAL CHARACTERISTICS
1)
PARAMETER TEST CONDITION PART SYMBOL MIN TYP. MAX UNIT
INPUT
Forward voltage I
F
= ± 10 mA V
F
1.2 1.55 V
Reverse current V
R
= 6.0 V I
R
0.1 100 mA
OUTPUT
Collector-emitter breakdown voltage I
C
= 10 µA BV
CEO
70 V
Emitter-collector breakdown voltage I
E
= 10 µA BV
ECO
7.0 V
Collector-emitter leakage current V
CE
= 10 V I
CEO
5.0 50 nA
COUPLER
Symmetry (CTR at + 10 mA)/(CTR at -10 mA) 0.5 1.0 2.0
Saturation voltage, collector-emitter I
F
= ± 16 mA, I
C
= 2.0 mA V
CEsat
0.4 V
CURRENT TRANSFER RATIO
PARAMETER TEST CONDITION PART SYMBOL MIN TYP. MAX UNIT
DC Current Transfer Ratio I
F
= ± 10 mA, V
CE
= 5.0 V CTR
DC
20 %
SAFETY AND INSULATION RATINGS
1)
PARAMETER TEST CONDITION SYMBOL MIN TYP. MAX UNIT
Climatic classification (according to IEC 68 part 1) 55/100/21
Comparative tracking index CTI 175 399
V
IOTM
6000 V
V
IORM
560 V
P
SO
350 mW
I
SI
150 mA
T
SI
165 °C
Creepage 4mm
Clearance 4mm
Insulation thickness, reinforced rated per IEC60950 2.10.5.1 0.2 mm
ABSOLUTE MAXIMUM RATINGS
1)
PARAMETER TEST CONDITION SYMBOL VALUE UNIT