FRS-R-80

Fusetron™ 600V Class RK5
FRS-R — 600 Vac/300 Vdc, 65-600 A, dual element, time-delay fuses
Catalog symbol:
•
FRS-R-(amp)
Description:
Advanced protection, energy efficient Class RK5
dual element, current-limiting, time-delay fuses.
Time-delay – 10 seconds (minimum) at 500% of
rated current.
Specications:
Ratings
•
Volts — 600Vac, 300Vdc
•
Amps — 65-600A
•
Interrupting rating
• 200 kA Vac RMS Sym
• 20 kA Vdc
Agency information
•
UL
®
Listed, Std. 248-12, Class RK5, Guide
JDDZ, File E4273
•
CSA
®
Certified, C22.2 No. 248.12, Class
1422-02, File 53787
•
CE
Catalog numbers (amps)
FRS-R-65 FRS-R-125 FRS-R-350
FRS-R-70 FRS-R-150 FRS-R-400
FRS-R-75 FRS-R-175 FRS-R-450
FRS-R-80 FRS-R-200 FRS-R-500
FRS-R-90 FRS-R-225 FRS-R-600
FRS-R-100 FRS-R-250
FRS-R-110 FRS-R-300
Carton quantity
Amp ratings Carton Qty.
65–100 1
101–200 1
201–400 1
401–600 1
Features:
•
Provides motor overload, ground fault
and short-circuit protection. When used in
circuits subject to surge currents such as
those caused by motors, transformers and
other inductive components, these fuses
can be sized close to full-load amps to give
maximum overcurrent protection
•
The time-delay feature makes it possible
to use fuse amp ratings which are much
smaller than those of non-time delay
fuses. Considerable cost saving occurs by
permitting the use of smaller size switches,
panels and fuses themselves
•
Provides a good degree of short-circuit
protection (greater current-limitation) to help
protect downstream components from high
fault currents
•
Gives motor running back-up protection to
motors without extra cost
•
Helps protect motors against burnout from
overloads and single-phasing when sized
properly
•
Simplifies and improves blackout prevention
(selective coordination ratios)
•
Dual-element fuses can be applied in
circuits subject to temporary motor
overloads and surge currents to provide
both high-performance, short-circuit and
overload protection
Dimensions - in:
A
B
Amp ratings A B
65-100 7.88 1.11
110-200 9.63 1.61
225-400 11.63 2.34
450-600 13.38 2.88
Technical Data 1018
Effective May 2016
Supersedes July 2013
BUSSM ANN
SERIES
2
Eaton.com/bussmannseries
TechnicalData1018
Effective May 2016
Fusetron™ 600 V Class RK5
FRS-R — 600 Vac/300 Vdc, 65-600 A,
dual element, time-delay fuses
Recommended fuse blocks
Fuse amps 1-Pole 2-Pole 3-Pole
70-100 RM60100-1CR RM60100-2CR RM60100-3CR
110-200 RM60200-1CR RM60200-2CR RM60200-3CR
225-400 RM60400-1CR RM60400-2CR RM60400-3CR
450-600 RM60600-1CR RM60600-2CR RM60100-3CR
For additional information on the RM600 volt fuse blocks, see data sheet
No. 10489.
Fuse reducers for class R fuses
Equipment
fuse clips
Desired fuse
(case) size
Catalog numbers
(pairs) 600 V
200 A 100 A NO.2621-R
400 A 100 A NO.2641-R
200 A NO.642-R
100 A NO.2661-R
600 A 200 A NO.2662-R
400 A NO.2664-R†
Single reducer only (pair not required).
For additional information on Class R fuse reducers, see data
sheet No. 1118.
Prosp.
S.C.C.
Let-through current
(apparent RMS symmetrical vs. fuse rating)
100A 200A 400A 600A
5000 3000 4000 5000 5000
10,000 4000 5000 9000 10,000
15,000 4000 6000 10,000 14,000
20,000 5000 7000 11,000 15,000
25,000 5000 7000 12,000 17,000
30,000 5000 8000 13,000 18,000
35,000 5000 8000 13,000 18,000
40,000 6000 9000 14,000 19,000
50,000 6000 9000 14,000 20,000
60,000 6000 10,000 15,000 22,000
70,000 7000 11,000 17,000 23,000
80,000 7000 12,000 17,000 23,000
90,000 7000 12,000 17,000 24,000
100,000 8000 13,000 18,000 25,000
150,000 9000 14,000 21,000 27,000
200,000 9000 16,000 23,000 32,000
400000
9000
8000
7000
7000
6000
6000
300000
200000
100000
5000
4000
4000
90000
3000
2000
1000
3000
70000
80000
70000
60000
B
A
50000
60000
200000
20000
2000
40000
100000
50000
10000
5000
1000
30000
90000
80000
40000
9000
8000
30000
20000
10000
600A
400A
200A
100A
Amp rating
Prospective short-circuit current - symmetrical RMS amps
Instantaneous peak let-through current in amps
0.1
1
10
100
300
1000
10,000
0.01
100
20,000
Time in seconds
RMS symmetrical current in amps
Amp rating
20
15A
30A
60A
100A
200
A
400
A
600
A
Time-current curves - average melt
Current-Limitation curves
Current-limiting effects
TechnicalData1018
Effective May 2016
Fusetron™ 600 V Class RK5
FRS-R — 600 Vac/300 Vdc, 65-600 A,
dual element, time-delay fuses
For Eatons Bussmann series
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries
Follow us on social media to get the
latest product and support information.
Eaton, Bussmann and Fusetron are
valuable trademarks of Eaton in the US
and other countries. You are not permitted
to use the Eaton trademarks without prior
written consent of Eaton.
CSA is a registered trademark of the
Canadian Standards Group.
UL is a registered trademark of the
Underwriters Laboratories, Inc.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
© 2016 Eaton
All Rights Reserved
Printed in USA
Publication No. 1018 – SB13729 / APT
May 2016
The only controlled copy of this Data Sheet is the electronic read-only version located on the Eaton Network Drive. All other copies of this
document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical
information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction
ofany products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice,
any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible
applications.

FRS-R-80

Mfr. #:
Manufacturer:
Description:
Industrial & Electrical Fuses 600V 80A Dual Elemtent Time Delay
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: