TLI4946
Specification
Datasheet 12 Rev. 1.0, 2009-05-04
3.3 Operating Range
The following operating conditions must not be exceeded in order to ensure correct operation of the TLI4946xy.
All parameters specified in the following sections refer to these operating conditions unless otherwise mentioned.
3.4 Electrical Characteristics
Product characteristics include the spread of values guaranteed within the specified voltage and ambient
temperature range. typical characteristics are the median of the production (at V
s
=12V and T
A
=25°C).
Table 4 Operating Range
Parameter Symbol Values Unit Note / Test Condition
Min. Typ. Max.
Supply Voltage
V
S
2.7 – 18 V
Output Voltage
V
Q
-0.7 – 18 V
Output Current
I
Q
0–20 mA
Maximum Ambient Temperature
T
A
-40 – 125 °C
Table 5 Electrical Characteristics
Parameter Symbol Values Unit Note / Test Condition
Min. Typ. Max.
Supply Current
I
S
246 mAV
S
=2.7 V...18 V
Reverse Current
I
SR
00.21 mAV
S
=-18 V
Output Saturation Voltage
V
QSAT
–0.30.6 V I
Q
=20 mA
Output leakage current
I
QLEAK
–0.0510 µA V
Q
=18 V
Output fall time
1)
1) See Figure 6
t
f
–0.021 µs R
L
=1.2k Ω, C
L
=50 pF
Output rise time
1)
t
r
–0.41 µs
Chopper frequency
f
OSC
–320– kHz
Switching frequency
f
SW
0–15
2)
2) To operate the sensor at maximum switching frequency, the value of the magnetic signal amplitude must be 1.4 times
higher than the static fields. This is due to the -3 dB corner frequency of the low pass filter in the signal path.
kHz
Delay time
3)
3) Systematic delay between magnetic threshold reached and output.
t
d
–13– µs
Output jitter
4)
4) Jitter is the unpredictable deviation of the output switching delay.
t
QJ
–1– µs
RMS
Typical value for a 1 kHz
square wave signal
Power-on Time
5)
5) Time from applying V
S
. > 2.7 V to the sensor until the output state is valid.
t
PON
–13– µs V
S
> 2.7 V
Thermal Resistance junction to
ambient
6)
6)Relationship between junction and ambient temperature: T
J
=T
amb
+ R
thja
. (V
S
. I
S
+ V
QS
. I
Q
).
R
thja
– 100 – K/W TLI4946K, TLI4946-2K
– 190 K/W TLI4946-2L