7–23
KILOVAC High Voltage DC Contactors
KILOVAC High Voltage
DC Contactors
7
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
KILOVAC EV200B Series Contactor With 1 Form Y (SPST-NC)
Contacts Rated 500+ Amps, 12-900 Vdc
Product Facts
n Normally closed version of
popular EV200 series
c
ontactors
n Designed to be the
smallest, lowest cost,
lightest weight sealed
contactor in the industry at
i
ts current rating
n Optional auxiliary contacts
for monitoring position of
power contacts
n Hermetically sealed —
operates in explosive/harsh
environments with no
oxidation or contamination
of coil or contacts during
long periods of non-
operation
n Not position sensitive, can
be mounted in any
orientation
n RoHS versions available
Ordering Information
Typical Part Number 䊳 EV200 BAANA
Series:
EV200 = 500+ Amp, 12-900VDC Contactor
Contact Form:
B = Normally Closed
D = Normally Closed, 1 SPDT Aux.
Coil Voltage (with Economizer):
A = 12/24 Vdc
Coil Terminals:
A = 15.3 in. (300 mm)
Coil Terminal Connector:
N = None
Mounting & Power Terminations:
A = Bottom Mount & Male 10 Max. M8
Threaded Terminals
Physical Data
Contact Arrangements —
Main Contacts — SPST, Normally
Closed
Dimensions — See drawing
Weight, Nominal — .95 lb. (.43 kg)
Environmental Data
Shock, 11ms 1/2 Sine
(Operating) — 30 G
p
eak
(Closed)
10 G
peak
(Open)
Sine Vibration, 10 G
peak
—
55-2000 Hz
Random Vibration, 7.1 Grms —
15 Hz (.001 G
2
/Hz), 100 Hz (.04 G
2
/Hz),
1000 Hz (.04 G
2
/Hz), 1500 Hz (.02 G
2
/Hz)
Operating Temperature Range —
-40°C to +85°C
Electrical Data
Voltage Rating —
Main Contacts (Max) — 750 Vdc
Current Rating, Continuous —
Main Contacts
1
— 500A
Contact Resistance —
Main Contacts
2
—
0.2 mΩ max above 300A
0.3 mΩ max between 50 and 300A
Hot Switching Performance
(Positive Polarity)
3
—
200A make/ break @ 270Vdc —
10,000 cycles
600A make/ break @ 360Vdc —
100 cycles
800A break only @ 360Vdc —
15 cycles
1500A break only @ 360Vdc — 1 cycle
Mechanical Life (Min) —
1 million cycles
Dielectric Withstand Voltage —
Terminal to Terminal/ Terminals to Coil —
1mA max @ 2,200 Vrms
Insulation Resistance —
Terminal to Terminal/ Terminals to Coil —
100MΩ min @ 500Vdc new
50MΩ min @ 500Vdc end of life
Coil Data
4
Nominal Coil Voltage
5
—
Low range — 9.6-14 Vdc
High range — 19-28 Vdc
Pick Up (Max) @ 25°C —
9.6/18.5 Vdc
Pick Up @ Max Coil Temperature —
10.5/22 Vdc
Hold (Min) — 6/12 Vdc
Dropout (Min) — 4/9 Vdc
Pickup Current, Peak
6
@ 25°C —
6 A
Operate Specs @ 25°C —
Operate Time (Typ) — 15 ms
Operate Bounce (Max) — 5 ms
Release Time (Typ) — 15 ms
Economizer Operating Frequency —
18 kHz
Hold Current —
0.9A/12 Vdc
0.3A/24 Vdc
Notes:
1
Ambient conditions and conductor
d
esign affect rating. Terminal tem-
perature rise should be 75°C max
a
bove ambient. Keep relay termi-
nals below 150°C max continuous,
1
75°C max for two hours, and
200°C for 1 minute.
2
Stabilized reading. Contact resist-
a
nce may exceed spec in the first
10 minutes of current carry.
3
U
nits are polarity sensitive.
Approximately 50% de-rating
for reverse polarity switching.
Consult factory for review of
specific requirements.
4
Over temperature range unless
noted.
5
Voltage ranged sensed by contac-
tor 10 ms after application of
source voltage.
6
Pickup duration 100 ms.