POE30U-560(G)-HT Characteristics WWW.PHIHONG.COM
INPUT:
AC Input Voltage Range
85 to 264VAC
AC Input Voltage Rating
100 to 240VAC
AC Input Frequency
47-63Hz
AC Input Current
15A (RMS) maximum for 115VAC
20A (RMS) maximum for 230VAC
Leakage Current
0.25mA maximum for 264VAC 50Hz for input to PE
3.5mA maximum for 264VAC 50Hz for input to output
AC Inrush Current
15A (RMS) maximum for 115VAC
20A (RMS) maximum for 230VAC
OUTPUT:
Total Output Power
30W at 56V DC
DC Offset
No data degradation with DC imbalance 18mA per min.
Efficiency
75% (typical) at maximum load, and 120VAC 60Hz
Hold-up Time
16mS min. and 120VAC at maximum load
Transient O/P Voltage Protection
60V maximum zener clamp
ENVIRONMENTAL:
Temperature
Operation -20 to +55°C
Non-operation -40 to +85°C
Humidity 10 to 90%
EMC
FCC Part 15 Class B
EN55022 Class B
Isolation Test
Primary to Secondary: 4242VDC for 1 minute 10mA
Primary to F.G.: 2121VDC for 1 minute
Output to F.G.: 2121VDC
Immunity
ESD: EN61000-4-2. Level 3
RS: EN61000-4-3. Level 2
EFT: EN61000-4-4. Level 2
Surge: EN61000-4-5. Level 3
CS: EN61000-4-6. Level 2
Voltage Dips EN61000-4-11
Harmonic: EN61000-3-2
Insulation Resistance
Primary to Secondary: >10M OHM 500VDC
Primary to Field Ground: >10M OHM 500VDC
IEEE 802.3at Interoperability
UNH Interoperability report available upon request
FEATURE:
Cisco
No extern parts required for Legacy devices:
VoIP Phones:
7910, 7912, 7940, 7960
Access Points:
1040, 1140, 1250, 1260, 3500
Over Voltage/Current, Short Circuit Protection
The output can be shorted permanently without damage
Indicators
Green LED 1: Power detected “ON”
Green LED 2: Valid “PoE Plus” load detected and
connected
Green LED 3: Valid IEEE802.3af load detected and
connected
Input Connector
IEC320 inlet 3 pin
Output Connection
+pins 3, 6
-pins 1, 2
Dimension Diagram Unit: mm