ADT7301
Rev. B | Page 6 of 16
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
1
2
3
GND
TOP VIEW
(Not to Scale)
02884-0-004
6
5
4
ADT7301
DIN
V
DD
DOUT
CS
SCLK
Figure 4. SOT-23 Pin Configuration
1
2
3
4
NC
TOP VIEW
(Not to Scale)
8
7
6
5
ADT7301
DOUT
NC
GND
SCLK
V
DD
DIN
02884-0-005
CS
Figure 5. MSOP Pin Configuration
Table 4. Pin Function Descriptions
SOT-23
Pin No.
MSOP
Pin No. Mnemonic Description
1 7 GND Analog and Digital Ground.
2 6 DIN Serial Data Input. Serial data to be loaded to the part’s control register is provided on this input.
Data is clocked into the control register on the rising edge of SCLK.
3 5 V
DD
Positive Supply Voltage, 2.7 V to 5.25 V.
4 4 SCLK Serial Clock Input. This is the clock input for the serial port. The serial clock is used to clock data out
of the ADT7301’s temperature value register and to clock data into the ADT7301’s control register.
5 3
CS
Chip Select Input. Logic input. The device is selected when this input is low. The SCLK input is
disabled when this pin is high.
6 2 DOUT Serial Data Output. Logic output. Data is clocked out of the temperature value register at this pin.
Data is clocked out on the falling edge of SCLK.
1, 8 NC No Connect.