MC100EPT23
www.onsemi.com
4
Table 4. PECL DC CHARACTERISTICS (V
CC
= 3.3 V, GND = 0 V (Note 1))
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
CCH
Power Supply Current (Outputs set to HIGH) 10 20 35 10 20 35 10 20 35 mA
I
CCL
Power Supply Current (Outputs set to LOW) 15 27 40 15 27 40 15 27 40 mA
V
IH
Input HIGH Voltage 2075 2420 2075 2420 2075 2420 mV
V
IL
Input LOW Voltage 1355 1675 1355 1675 1355 1675 mV
V
IHCMR
Input HIGH Voltage Common Mode Range
(Note 2)
1.2 3.3 1.2 3.3 1.2 3.3 V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current
D
D
−150
−150
−150
−150
−150
−150
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. All values vary 1:1 with V
CC
.
2. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.
Table 5. LVTTL/LVCMOS OUTPUT DC CHARACTERISTICS (V
CC
= 3.3 V, GND = 0.0 V, T
A
= −40°C to 85°C)
Symbol
Characteristic Condition Min Typ Max Unit
V
OH
Output HIGH Voltage I
OH
= −3.0 mA 2.4 V
V
OL
Output LOW Voltage I
OL
= 24 mA 0.5 V
I
OS
Output Short Circuit Current −180 −50 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 6. AC CHARACTERISTICS (V
CC
= 3.0 V to 3.6 V, GND = 0.0 V (Note 1))
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
f
max
Maximum Frequency (Figure 2) 275 350 275 350 275 350 MHz
t
PLH
,
t
PHL
Propagation Delay to
Output Differential (Note 2)
1.1 1.5 1.8 1.1 1.5 1.8 1.1 1.5 1.8 ns
t
SK+
+
t
SK−
−
t
SKPP
Output-to-Output Skew++
Output-to-Output Skew−−
Part-to-Part Skew (Note 3)
15
35
70
60
80
500
15
40
70
70
80
500
30
40
140
125
80
500
ps
t
JITTER
Random Clock Jitter (RMS) (Figure 2) 5 10 5 10 5 10 ps
V
PP
Input Voltage Swing (Differential Configuration) 150 800 1200 150 800 1200 150 800 1200 mV
t
r
t
f
Output Rise/Fall Times (0.8 V − 2.0 V)
Q, Q
330 600 900 330 600 900 330 650 900 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Measured with a 750 mV 50% duty-cycle clock source. R
L
= 500 W to GND and C
L
= 20 pF to GND. Refer to Figure 3.
2. Reference (V
CC
= 3.3V ± 5%; GND = 0 V)
3. Skews are measured between outputs under identical conditions.