TPI 100-115A-J

http://www.tracopower.com Page 1 of 4
AC/DC Power Supplies
TPI 100A Series, 100 Watt
Features
Highest power density open frame
100 W power supply in 2” x 3” package
I/O reinforced isolation 3000 VDC
Ready to meet ErP directive,
< 0.3 W no load power consumption
Highest efficiency 91 to 92%
across 10% – 100% load range
Active power factor correction (>95)
Protection class II prepared
Operating up to 5000 m altitude
Adjustable output voltage
3-year product warranty
The TPI 100A Series of 100 Watt AC/DC power supplies features a 3000 VAC
I/O reinforced isolation. Excellent efficiency of up to 92% allows a high power
density for the standard 2.0” x 3.0” packaging format. The full load operating
temperature range is –40°C to +50°C while it goes up to 80°C with load derating.
The power supplies are designed to meet the ErP directive (< 0.3W no load power
consumption).
They come with an active power factor correction and the EMC characteristic is
dedicated for applications in industrial and domestic fields.
High reliability is provided by use of industrial quality grade components and an
excellent thermal management. It makes the products an ideal solution for any de-
manding industrial devices and space critical applications.
Order code Output voltage
(adjustment range)
Output current
max.
Efficiency
max.
TPI 100-112A-J 12 VDC (10.8 - 13.2) 8.34 A 91 %
TPI 100-115A-J 15 VDC (13.5 - 16.5) 6.67 A 92 %
TPI 100-124A-J 24 VDC (21.6 - 26.4) 4.17 A 92 %
TPI 100-128A-J 28 VDC (25.2 - 30.8) 3.58 A 92 %
TPI 100-136A-J 36 VDC (32.4 - 39.6) 2.78 A 91 %
TPI 100-148A-J 48 VDC (43.2 - 52.8) 2.09 A 91 %
Models
prepared
C B
Scheme
UL 60950-1
http://www.tracopower.com Page 2 of 4
AC/DC Power Supplies
TPI 100A Series 100 Watt
Input Specifications
Input voltage range – AC range (universal input) 85 – 264 VAC
– DC range 120 – 370 VDC
Input frequency 47 – 63 Hz
Input current at full load – at 115 VAC / 230 VAC 1.15 A max. / 0.55 A max.
Input protection T3.15 A/250 VAC (internal fuse in both line & neutral)
Zero load power consumption 0.3 W (acc. ErP directive)
Harmonic limits EN 61000-3-2, Class A & D
– Power factor 0.95
Inrush current at 230 Vac 100 A max.
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation 0.2 % max.
– Load variation (0 - 100%) 0.5 % max.
Minimum load not required
Temperature coefficient 0.02 %/K
Hold-up time – Vin = 115 VAC / 230 VAC 22 ms min.
Start-up time <1s
Rise time 20ms typ.
Output voltage adjustment ±10 %
Ripple and noise (20Mhz Bandwidth) 12 VDC model: 120 mVp-p typ. with cap. 10µF/25V 1206 X7R MLCC
15 VDC model: 150 mVp-p typ. with cap. 10µF/25V 1206 X7R MLCC
24 VDC model: 160 mVp-p typ. with cap. 1µF/50V 1206 X7R MLCC
28 VDC model: 180 mVp-p typ. with cap. 1µF/50V 1206 X7R MLCC
36 VDC model: 190 mVp-p typ. with cap. 1µF/50V 1206 X7R MLCC
48 VDC model: 340 mVp-p typ. with cap. 0.1µF/100V 1206 X7R MLCC
Overvoltage protection 115 – 135 % of nominal Vout
Overload protection by current limit (hiccup) at 115 – 150 % Iout max.
Short circuit protection continuous (automatic recovery)
Transiente response – Peak deviation 3 % of Vout
(25% load step change) – Recovery time 500µs
General Specifications
Operating temperature –40 °C to +80 °C with derating, see below
start up at -40°: 80% max. load at Vin > 100 VAC
start up at -40°: 100% max. load at Vin > 200 VAC
Output power derating – Temperature 2.33 %/K above +50°C
– Low input voltage 1.33 %/V below 100 VAC
Storage temperature –40°C to +8C
Humidity (non condensing) 5 – 95 % rel. H max.
Altitude during operation 5000 m
Switching frequency 60 kHz typ. (pulse width modulation)
Isolation voltage 1min (reinforced insulation)
Input / Output 3000 VAC
– Input / Case 1500 VAC
Leakage current (at 264 VAC/60Hz) 300 µA max.
Isolation resistance (at 500 VDC) 100 Mohm min.
Reliability, calculated MTBF at +2C acc. to IEC 61709 > 790‘000 h
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Supplies
TPI 100A Series 100 Watt
General Specifications
Protection class class II prepared
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B
(EMC), emissions – Harmonic current emissions IEC / EN 61000-3-2, class A & D
– Voltage flicker IEC / EN 61000-3-3, (class tba.)
– Radiated input suppression EN 55011, class A
Electromagnets compatibility – Electrostatic discharge ESD IEC / EN 61000-4-2, 8kV/6kV perf. criteria A
(EMC), immunity – RF field immunity IEC / EN 61000-4-3, 20V/m perf. criteria A
– Electrical fast transients/burst immunity IEC / EN 61000-4-4, ± 2kV perf. criteria A
– Surge IEC / EN 61000-4-5, ± 1kV/± 2kV perf. criteria A
– Conducted RF IEC / EN 61000-4-6, 20 Vr.m.s perf. criteria A
– Magnetic field IEC / EN 61000-4-8, 10A/m perf. criteria A
– Dip an interruptions IEC / EN 61000-4-11, (criteria tba.)
Safety standards – Information technology equipment UL 60950-1, IEC/EN 60950-1
– Certification documents www.tracopower.com/overview/tpi100a
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10–55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 10g half sine, 11msShock
20 G (3 directions each 3 times)
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Connection pin connector
020406080
100
80
60
40
20
0
Output Power [%]
Ambient Temperature [°C]
(for horizontal mounting)
-25
Power derating depending on temperature

TPI 100-115A-J

Mfr. #:
Manufacturer:
TRACO Power
Description:
Switching Power Supplies
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union