9
Parameter Sym. Device Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay HCPL-0370/3700 4.0
Time to Logic Low t
PHL
15.0 µs R
L
= 4.7 kW, C
L
= 30 pF 10
at Output HCPL-3760 4.5
7, 10
Propagation Delay HCPL-0370/3700 10.0
Time to Logic High t
PLH
40.0 µs R
L
= 4.7 kW, C
L
= 30 pF 11
at Output HCPL-3760 8.0
HCPL-0370/3700 20
Output Rise Time t
r
µs R
L
= 4.7 kW, C
L
= 30 pF
(10-90%) HCPL-3760 14
8
HCPL-0370/3700 0.3
Output Fall Time t
f
µs R
L
= 4.7 kW, C
L
= 30 pF
(90-10%) HCPL-3760 0.4
Common Mode I
IN
= 0 mA, R
L
= 4.7 kW,
Transient Immunity |CM
H
| 4000 V/µs V
O min
= 2.0 V, V
CM
= 1400 V
at Logic High Output
9, 11 12, 13
Common Mode HCPL-0370/3700 I
IN
= 3.11 mA R
L
= 4.7 kW,
Transient Immunity |CM
L
| 600 V/µs V
O max
= 0.8 V,
at Logic Low Output HCPL-3760 I
IN
= 1.56 mA V
CM
= 140 V
Switching Specifications
T
A
= 25°C, V
CC
= 5.0 V, Unless Otherwise Specified.
Package Characteristics
Over Recommended Temperature T
A
= 0°C to 70°C, Unless Otherwise Specified.
Parameter Sym. Min. Typ.
[9]
Max. Units Conditions Fig. Note
Input-Output Momentary V
ISO
3750 V rms RH 50%, t = 1 min; 16,
Withstand Voltage* T
A
= 25°C 17
Option 020 5000 18
Input-Output Resistance R
I-O
10
12
W V
I-O
= 500 Vdc 16
Input-Output Capacitance C
I-O
0.6 pF f = 1 MHz; V
I-O
= 0 Vdc
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Table (if applicable), your equipment
level safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”