SA2-7200-CLT-STD

Electrical Characteristics
SA2 Series High Voltage Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
Operating Temperature Range .................................................................................................................................................... -40 °C to +125 °C
Storage Temperature Range ....................................................................................................................................................... -65 °C to +125 °C
Device Plating............................................................................................................................................................................................ Matte-Sn
Description
Bourns
®
SA2 Series two-electrode High Voltage Gas Discharge Tube devices are designed
for high isolation applications. The series offers high insulation resistance over a wide
temperature range and is offered with DC breakdowns from 2.4 kV to 7.2 kV. Other
customized voltages between 2 kV and 7.2 kV are available upon request.
Part No.
Device Specifi cations Life Ratings
DC Breakdown Voltage
@ 500 V/s
Impulse
Breakdown
Ramp
Insulation
Resistance
@ 250 Vdc
Arc
Voltage
@ 5A
min.
Capacitance
@ 1 MHz
Nominal Impulse
Discharge
Nom.
DC
Break-
down
After
Life
Min. Typ. Max. Tol. Max. Typ. Min. Typ. Max.
1
Operation
10
Operations
SA2-2400-Dxx-STD 2040 2400 2880
-15 % to
+20 %
3800 V
@1
kV/µs
10 G Ohm 20 V 1 pF
10 kA,
8/20 µs
5 kA,
8/20 µs,
±5
operations
in each
polarity
>2.0 kV
SA2-2400-Cxx-STD 1920 2400 2880
-20 % to
+20 %
>1.9 kV
SA2-3000-Dxx-STD 2550 3000 3600
-15 % to
+20 %
4500 V
@7.5
kV/µs
>2.4 kV
SA2-3000-Cxx-STD 2400 3000 3600
-20 % to
+20 %
>2.3 kV
SA2-3600-Dxx-STD 3060 3600 4320
-15 % to
+20 %
5400 V
@7.5
kV/µs
>3.0 kV
SA2-3600-Cxx-STD 2880 3600 4320
-20 % to
+20 %
>2.8 kV
SA2-5500-Dxx-STD 4675 5500 6600
-15 % to
+20 %
8000 V
@7.5
kV/µs
>4.4 kV
SA2-5500-Cxx-STD 4400 5500 6600
-20 % to
+20 %
>4.2 kV
SA2-6200-Dxx-STD 5270 6200 7440
-15 % to
+20 %
8000 V
@7.5
kV/µs
>5.2 kV
SA2-6200-Cxx-STD 4960 6200 7440
-20 % to
+20 %
>4.9 kV
SA2-6300-Dxx-STD 5355 6300 7560
-15 % to
+20 %
9200 V
@7.5
kV/µs
>5.3 kV
SA2-6300-Cxx-STD 5040 6300 7560
-20 % to
+20 %
>5.0 kV
SA2-7200-Dxx-STD 6120 7200 8640
-15 % to
+20 %
10000 V
@1
kV/µs
>6.3 kV
SA2-7200-Cxx-STD 5760 7200 8640
-20 % to
+20 %
>6.0 kV
Features
Formerly a product
High insulation resistance
Quick response, long service life
Available DC breakdown range:
2.4 kV to 7.2 kV
Wide operating temperature range
RoHS compliant*
Applications
Street lighting
Medical devices
Air conditioning
Power supplies
Projectors
Welders
Agency Recognition
Agency Category
Agency
File No.
UL UL 1449 E313168
Note: Model SA2-7200 specifi cation is based on the customer providing suffi cient encapsulation/working environment for the component
to avoid outside surface breakdown (e.g., non-contaminated equivalent surface in RH 40 % reaches breakdown at 10-12 kV).
Product Characteristics
*RoHS COMPLIANT
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
SA2 Series High Voltage Gas Discharge Tube
Environmental Characteristics
Section Category Test Condition
IEC 60068-2-13 test M Operational Low Air Pressure Temp. +55 °C, Time 0.5 Sec., Pressure 600 hPa
IEC 60068-2-1, test Ab
Non-
Operational
Cold -40 °C, 96 Hours
IEC 60068-2-2, test Bb Dry Heat +100 °C, 96 Hours
IEC 60068-2-30, test Ca Damp Heat, Steady State +40 °C, 93 % RH, 21 Days
IEC 60068-2-14, test Na Rapid Change in Temperature Upper Temp. +100 ° C, Lower Temp. -40 °C, 5 Cycles
IEC 60068-2-6, test Fc Vibration 10-55 Hz, 30 Min. per Axis, Double Amplitude 0.70 Min.
IEC 60068-2-27, test Ea Shock Test 30 g, 11 ms, Half Sine Pulse
IEC 60068-2-20, test Ta Solderability Method 1, +235 °C, 2 Sec., Aging
IEC 60068-2-20, test Tb Resistance to Soldering Heat Method 1A, +260 °C, 5 Sec.
IEC 60068-2-21 Robustness of Terminations Ua1 (Tensile), Ua2 (Thrust), Ub (Bending) and Uc (Torsion)
How to Order
SA 2 - nnnn - x x x - STD
Series Designator
No. of Electrodes
2 = 2 Electrodes
Breakdown Voltage
2400 = 2400 V 6200 = 6200 V
3000 = 3000 V 6300 = 6300 V
3600 = 3600 V 7200 = 7200 V
5500 = 5500 V
Tolerance
C = -20 % to +20 %
D = -15 % to +20 %
Lead Shape
B = Bent Leads*
C = No Leads*
K = Bent Leads with Kinks*
K1 = Bent Leads with Kinks*
L = Straight Leads**
Packaging
B = Bulk
T = Tape & Reel
Standard or Modifi ed Product Indicator
STD = Standard
* Available in bulk packaging only.
** Bulk packaging available for straight lead devices ≤3600 V. Devices >3600 V available in tape and
reel only.
Typical Part Marking
.................................... SA2-xxxx
xxxx
60.0 - 85.0
(2.362 - 3.346)
TINNED LEADS
METAL ELECTRODE
CERAMIC INSULATOR
8.5 +0.1/-0.3
(.335 +.004/-.012)
DIA.
1.0
(.039)
DIA.
8.9 ± 0.4
(.350 ± .016)
METAL ELECTRODE
CERAMIC INSULATOR
8.5 +0.1/-0.3
(.335 +.004/-.012)
DIA.
8.9 ± 0.4
(.350 ± .016)
8.5 +0.1/-0.3
(.335 +.004/-.012)
DIA.
CERAMIC INSULATOR
METAL ELECTRODES
TINNED LEADS
8.9 ± 0.4
(.350 ± .016)
7.5 ± 0.5
(.295 ± .020)
3.6 ± 0.5
(.142 ± .020)
15.0 ± 0.5
(.591 ± .020)
1.0
(.039)
DIA.
8.5 +0.1/-0.3
(.335 +.004/-.012)
DIA.
CERAMIC INSULATOR
METAL ELECTRODES
TINNED LEADS
8.9 ± 0.4
(.350 ± .016)
18.0 ± 0.5
(.709 ± .020)
1.0
(.039)
DIA.
15.0 ± 0.5
(.591 ± .020)
REF.
9.9
(.390)
14.2 ± 0.5
(.559 ± .020)
4.3 ± 0.5
(.169 ± .020)
CERAMIC INSULATOR
METAL ELECTRODES
TINNED LEADS
8.9 ± 0.4
(.350 ± .016)
17.2 ± 0.1
(.677 ± .004)
8.5 +0.1/-0.3
(.335 +.004/-.012)
DIA.
1.0 ± 0.02
(.039 ± .008)
DIA.
12.5 ± 0.5
(.492 ± .020)
7.0 ± 1.0
(.276 ± .039)
16.0 ± 1.0
(.630 ± .039)
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
SA2 Series High Voltage Gas Discharge Tube
Product Dimensions
SA2-xxxx-xLx
DIMENSIONS:
MM
(INCHES)
SA2-xxxx-xKx
SA2-xxxx-xCx
SA2-xxxx-xK1x
SA2-xxxx-xBx

SA2-7200-CLT-STD

Mfr. #:
Manufacturer:
Bourns
Description:
Gas Discharge Tubes / Gas Plasma Arrestors 7200volts 1pF STRAIGHT LEADS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: