Ratings
Ratings
Japan
(TDK Shonai Manufacturing Corporation/Yamagata)
Temperature rise: 20C° max.
Storage temperature range: -40C° to 105C°
Operating temperature range: -20C° to 105C°
Country of origin
Country of origin
GLF & GLC Series Basic Information
TDK Electronics Europe GmbH - September 2004 Copyright 2004 by TDK Electronics Europe GmbH. All rights reserved.
C
A B A
D
Dimension in [mm]
ABCD
[mm] [mm] [mm] [mm]
GLF1608Type 0.70 0.70 2.10 0.70
GLF2012Type
GLF201208Type
GLF2518Type
GLF251812Type
GLC2518Type
0.80 1.00 2.60 0.80
0.90 1.30 3.10 1.60
The Recommended Land Pattern
The Recommended Land Pattern
TDK Electronics Europe GmbH - September 2004 Copyright 2004 by TDK Electronics Europe GmbH. All rights reserved.
Test Item Test Condition Specification
Temperature characteristics The test shall be performed after the sample has stabilized in an
L
20
±10
%
ambient temperature of -40 to +105,and the value calculated based
L -40C 20C 105C
on the value applicable in a normal temperature of +20.
Avg. -3.91 0.00 3.81
Max. -3.09 0.00 4.79
Min. -4.55 0.00 2.50
Thermal shock The test shall be performed upon completion of 100 cycles in accordance No mechanical damege.
with the conditions in the figure below, the measurement shall be made L/Lo±10%
L Initial Final
after the sample has been left in a normal temperature and normal
Avg. 0.00 0.22
humidity more than 12hours.
Max. 0.00 1.38
Min. 0.00 -0.69
Low temperature storage This test shall be performed upon completion of 1000±12hours in an No mechanical damege.
atmosphere with a temperature of -40±2 Upon completion of the test, L/Lo±10%
L Initial Final
the measurement shall be made after The sample has been left in a
Avg. 0.00 1.22
normal temperature and normal humidity more than 12hours.
Max. 0.00 3.56
Min. 0.00 -0.32
Continuous operation The sample shall be left for 1000±12hours in an atmosphere with a No mechanical damege.
in high temperature temperature of +105±2, under supplying rated current.Upon L/Lo±10%
L Initial Final
completion of the test, the measurement shall be made after the sample
Avg. 0.00 0.75
has been left in a normal temperature and normal humidiy more than
Max. 0.00 1.52
12hours.
Min. 0.00 0.22
Continuous operation The sample shall be left for 1000±12hours in an atmosphere with a No mechanical damege.
in moisture temperature of +60±3 and a humidity(RH)of 90-95%,under L/Lo±10%
L Initial Final
supplying rated current.Upon completion of the test,the measurement
Avg. 0.00 0.51
shall be made after the sample has been left in a normal temprature
Max. 0.00 2.14
and normal humidity mora than 12hours.
Min. 0.00 -0.49
12hours.
TEST RESULT
+105
+20
-40
30min 30min
1c y c l e
Reliability requirements
Reliability requirements

GLF201208T220M

Mfr. #:
Manufacturer:
TDK
Description:
FIXED IND 22UH 150MA 3.5 OHM SMD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS