NOTES ON HANDLING
1. Recommended soldering conditions
(1) Infrared reflow soldering
Peak reflow temperature 260°C or below (package surface temperature)
Time of peak reflow temperature 10 seconds or less
Time of temperature higher than 220°C 60 seconds or less
Time to preheat temperature from 120 to 180°C 120±30 s
Number of reflows Three
Flux Rosin flux containing small amount of chlorine (The flux with a
maximum chlorine content of 0.2 Wt% is recommended.)
120±30 s
(preheating)
220˚C
180˚C
Package Surface Temperature T (˚C)
Time (s)
Recommended Temperature Profile of Infrared Reflow
(heating)
to 10 s
to 60 s
260˚C MAX.
120˚C
(2) Wave soldering
• Temperature 260°C or below (molten solder temperature)
Time 10 seconds or less
• Preheating conditions 120°C or below (package surface temperature)
Number of times One (Allowed to be dipped in solder including plastic mold portion.)
Flux Rosin flux containing small amount of chlorine (The flux with a maximum chlorine
content of 0.2 Wt% is recommended.)
(3) Cautions
• Fluxes
Avoid removing the residual flux with freon-based and chlorine-based cleaning solvent.
2. Cautions regarding noise
Be aware that when voltage is applied suddenly between the photocoupler’s input and output or between
collector-emitters at startup, the output side may enter the on state, even if the voltage is within the absolute
maximum ratings.
Data Sheet PN10236EJ02V0DS
19
PS2565-1,-2,-4,PS2565L-1,-2,-4,PS2565L1-1,-2,-4,PS2565L2-1,-2,-4
USAGE CAUTIONS
1. Protect against static electricity when handling.
2. Avoid storage at a high temperature and high humidity.
Data Sheet PN10236EJ02V0DS
20
PS2565-1,-2,-4,PS2565L-1,-2,-4,PS2565L1-1,-2,-4,PS2565L2-1,-2,-4
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT
Parameter Symbol Speck Unit
Application classification (DIN VDE 0109)
for rated line voltages 300 Vr.m.s.
for rated line voltages 600 Vr.m.s.
IV
III
Climatic test class (DIN IEC 68 Teil 1/09.80) 55/100/21
Dielectric strength
maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and random test)
U
pr = 1.2 × UIORM, Pd < 5 pC
U
IORM
Upr
890
1 068
V
peak
Vpeak
Test voltage (partial discharge test, procedure b for all devices test)
U
pr = 1.6 × UIORM, Pd < 5 pC
U
pr 1 424 Vpeak
Highest permissible overvoltage UTR 8 000 Vpeak
Degree of pollution (DIN VDE 0109) 2
Clearance distance > 7.0 mm
Creepage distance > 7.0 mm
Comparative tracking index (DIN IEC 112/VDE 0303 part 1) CTI 175
Material group (DIN VDE 0109) III a
Storage temperature range Tstg –55 to +150 °C
Operating temperature range TA –55 to +100 °C
Isolation resistance, minimum value
V
IO = 500 V dc at TA = 25°C
V
IO = 500 V dc at TA MAX. at least 100°C
Ris MIN.
Ris MIN.
10
12
10
11
Safety maximum ratings (maximum permissible in case of fault, see thermal
derating curve)
Package temperature
Current (input current I
F, Psi = 0)
Power (output or total power dissipation)
Isolation resistance
V
IO = 500 V dc at TA = 175°C (Tsi)
Tsi
Isi
Psi
Ris MIN.
175
400
700
10
9
°C
mA
mW
Data Sheet PN10236EJ02V0DS
21
PS2565-1,-2,-4,PS2565L-1,-2,-4,PS2565L1-1,-2,-4,PS2565L2-1,-2,-4

PS2565L-1-E3-K-A

Mfr. #:
Manufacturer:
CEL
Description:
Transistor Output Optocouplers Hi-Iso AC Input 1-Ch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet