IDT
®
Frequency Timing Generator for Peripherals 1604C—04/23/15
9FGP204
Frequency Timing Generator for Peripherals
9
Electrical Characteristics - DOT96SS 0.7V Current Mode Differential Pair
PARAMETER SYMBOL CONDITIONS* MIN TYP MAX UNITS Notes
Current Source Output
Impedance
Zo V
O
= V
x
3000
Ω
1
Voltage High VHigh 660 725 850 mV 1,3
Voltage Low VLow -150 51 150 mV 1,3
Max Voltage Vovs 764 1150 mV 1
Min Voltage Vuds -300 5 mV 1
Crossing Voltage (abs) Vx(abs) 250 372 550 mV 1
Crossing Voltage (var) d-Vcross
Variation of crossing over all
edges
140 mV 1
Long Accuracy ppm see Tperiod min-max values -100 -41 100 ppm 1,2
96.00MHz nominal 10.4156 10.4166 10.4176 ns 2
96.00MHz -0.5% spread 10.4417 10.4427 10.4437 ns 2
Absolute min period Tabsmin 96.00MHz nominal/-0.5% spread 10.1917 10.6937 ns 1,2
Rise Time t
V
OL
= 0.175V, V
OH
= 0.525V 175 361 700 ps 1,4
Fall Time t
f
V
OH
= 0.525V V
OL
= 0.175V 175 375 700 ps 1,4
Rise Time Variation d-t
V
OL
= 0.175V, V
OH
= 0.525V 107 125 ps 1
Fall Time Variation d-t
f
V
OH
= 0.525V V
OL
= 0.175V 107 125 ps 1
Rise/Fall Matching t
RFM
Single-ended measurement,
averaging on
15 20 % 1
Slew Rate t
SLEW
Differential Measurment 1 2 4 V/ns 1,5
Duty Cycle d
t3
Measurement from differential
wavefrom
45 51.3 55 % 1
Jitter, Cycle to cycle t
jcyc-cyc
Measurement from differential
wavefrom
54 250 ps 1
*T
A
= 0 - 70°C; V
DD
= 3.3 V +/-5%; C
L
=2pF, R
S
=33.2
Ω
, R
P
=49.9
Ω
, I
RE
= 475
Ω
1
Guaranteed by design and characterization, not 100% tested in production.
2
All Long Term Accuracy and Clock Period specifications are guaranteed assuming that 25MHz_x is tuned to exactly 25.000MHz
3
I
RE
= V
DD
/(3xR
R
). For R
R
= 475
Ω
(1%), I
RE
= 2.32mA. I
OH
= 6 x I
RE
and V
OH
= 0.7V @ Z
O
=50
Ω
.
4
Rise/fall time measured on single-ended waveform per CK410 specification.
5
Slew rate measured on differential waveform per CK505 specification.
Measurement on single ended
signal using absolute value.
Statistical measurement on single
ended signal
Average period Tperiod
Electrical Characteristics - REF - 25MHz
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Notes
Long Accuracy ppm see Tperiod min-max values -50 0 50 ppm 1,2
Clock period T
period
25.00MHz output nominal 39.998 40.000 40.002 ns 2
Output High Voltage V
OH
I
OH
= -1 mA 2.4 V 1
Output Low Voltage V
OL
I
OL
= 1 mA 0.4 V 1
V
OH
@MIN = 1.0 V -29 mA 1
V
OH
@MAX = 3.135 V -23 mA 1
V
OL
@ MIN = 1.95 V 29 mA 1
V
OL
@ MAX = 0.4 V 27 mA 1
Rise Time t
r1
V
OL
= 0.4 V, V
OH
= 2.4 V 1 1.14 2 ns 1
Fall Time t
f1
V
OH
= 2.4 V, V
OL
= 0.4 V 1 1.32 2 ns 1
Skew t
sk1
V
= 1.5 V 16 500 ps 1
Duty Cycle d
t1
V
= 1.5 V 45 53.2 55 % 1
Jitter, Cycle-cycle t
cyc-cyc
V
= 1.5 V 75 200 ps 1
*TA = 0 - 70°C; Supply Voltage VDD = 3.3 V +/-5%, CL = 5 pF with Rs as shown in the termination table (unless otherwise specified)
1
Guaranteed by design and characterization, not 100% tested in production.
2
All Long Term Accuracy and Clock Period specifications are guaranteed assuming that 25MHz_x is tuned to exactly 25.000MHz
I
OL
Output Low Current
I
OH
Output High Current