PS9117A
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT
<R>
Parameter Symbol Speck Unit
Application classification (DIN EN 60664-1 VDE0110 Part 1)
for rated line voltages ≤ 300 Vr.m.s.
for rated line voltages ≤ 600 Vr.m.s.
IV
III
Climatic test class (DIN EN 60664-1 VDE0110) 40/85/21
Dielectric strength
maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and random test)
U
pr = 1.5 × UIORM, Pd < 5 pC
U
IORM
Upr
707
1 061
V
peak
Vpeak
Test voltage (partial discharge test, procedure b for all devices)
U
pr = 1.875 × UIORM, Pd < 5 pC
U
pr 1 326 Vpeak
Highest permissible overvoltage UTR 6 000 Vpeak
Degree of pollution (DIN EN 60664-1 VDE0110 Part 1) 2
Clearance distance >4.2 mm
Creepage distance >4.2 mm
Comparative tracking index (DIN IEC 112/VDE 0303 Part 1) CTI 175
Material group (DIN EN 60664-1 VDE0110 Part 1) III a
Storage temperature range Tstg –55 to +125 °C
Operating temperature range TA –40 to +85 °C
Isolation resistance, minimum value
V
IO = 500 V dc at TA = 25°C
V
IO = 500 V dc at TA MAX. at least 100°C
Ris MIN.
Ris MIN.
10
12
10
11
Ω
Ω
Safety maximum ratings (maximum permissible in case of fault, see thermal
derating curve)
Package temperature
Current (input current I
F, Psi = 0)
Power (output or total power dissipation)
Isolation resistance
V
IO = 500 V dc at TA = Tsi
Tsi
Isi
Psi
Ris MIN.
150
200
300
10
9
°C
mA
mW
Ω
Data Sheet PN10646EJ04V0DS