2864163

https://www.phoenixcontact.com/pi/products/2864163
08/19/2018Page4/6
Signal conditioner-MINI MCR-SL-UI-UI-SP-NC-2864163
Technical data
EMC data
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 5 %
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 5 %
Designation Conducted interferences
Standards/regulations EN61000-4-6
Typical deviation from the measuring range final value 5 %
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Designation Conducted interferences
Standards/regulations EN61000-4-6
Electrical isolation Basic insulation according to EN 61010
Conformance CE-compliant
ATEX  II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
https://www.phoenixcontact.com/pi/products/2864163
08/19/2018Page5/6
Signal conditioner-MINI MCR-SL-UI-UI-SP-NC-2864163
Block diagram
Zone 2
Div. 2
passive
IN
Sensor / Field
OUT
PLC / DCS
4-wire
+
+
+
+
+24V
+24V
+24V
GND 3
GND 3
GND 2
active
GND 3
GND 1
OUT U,IIN U,I
1 5
2
6
7
8
3
4
OUT
U,I
GND
U
S
5
6
1
2
Dimensional drawing
93,1
6,2
102,5
Application drawing
0...20mA
24V
0...10V
24V
MINIMCR-SL-UI-UI
51
2
3
4
6
7
8
GND3
GND1
IN
GND2
OUT
UB+ UB+
GND3
Controlsystem
Levelgauge
Mainsvoltage
Level measurement
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GL / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / EAC Ex / ATEX / cULus Listed
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
https://www.phoenixcontact.com/pi/products/2864163
08/19/2018Page6/6
Signal conditioner-MINI MCR-SL-UI-UI-SP-NC-2864163
Approvals
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
GL
http://exchange.dnv.com/tari/ 24916-05 HH
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com

2864163

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules MCR ISOLATING AMP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet