Nexperia
HEF4073B
Triple 3-input AND gate
HEF4073B All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 4 — 6 October 2017
3 / 11
7 Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to V
SS
= 0 V (ground).
Symbol Parameter Conditions Min Max Unit
V
DD
supply voltage -0.5 +18 V
I
IK
input clamping current V
I
< -0.5 V or V
I
> V
DD
+ 0.5 V - ±10 mA
V
I
input voltage -0.5 V
DD
+ 0.5 V
I
OK
output clamping current V
O
< -0.5 V or V
O
> V
DD
+ 0.5 V - ±10 mA
I
I/O
input/output current - ±10 mA
I
DD
supply current - 50 mA
T
stg
storage temperature -65 +150 °C
T
amb
ambient temperature -40 +85 °C
P
tot
total power dissipation T
amb
= -40 °C to + 85 °C
[1]
- 500 mW
P power dissipation per output - 100 mW
[1] For SO14 packages: above T
amb
= 70 °C, P
tot
derates linearly with 8 mW/K.
8 Recommended operating conditions
Table 5. Recommended operating conditions
Symbol Parameter Conditions Min Max Unit
V
DD
supply voltage 3 15 V
V
I
input voltage 0 V
DD
V
T
amb
ambient temperature in free air -40 +85 °C
V
DD
= 5 V - 3.75 ns/V
V
DD
= 10 V - 0.5 ns/V
Δt/ΔV input transition rise and fall rate
V