Description
Tripp Lite's OMNIVSINT1500XL line interactive UPS system offers voltage regulation, surge suppression
and long lasting, expandable battery support for personal computers, internetworking equipment and other
sensitive electronics. Internal UPS circuits support entry level PC systems for up to 75 minutes during
power failures so that connected equipment can be shut down without data loss. Automatic Voltage
Regulation (AVR) circuits regulate brownouts as low as 151 and overvoltages up to 282 volts back to
usable 230V levels without using battery power. Offers complete desktop power protection in an attractive
black tower configuration. Includes 8 IEC320-C13 outlets with battery support and AC surge suppression.
USB port enables optional unattended system shutdown without data loss in the case of extended power
failure, USB cable included. PowerAlert software available via free download. Built-in single line RJ jacks
protect modem, fax machine, Ethernet, cordless phone or other peripheral with a standard dialup/DSL
phone connection. Built-in audible alarm and 4 front panel LEDs indicate line power status, battery power
status, battery low/replace status and voltage boost operation. 1500VA power handling ability supports
entry-level PCs, network workstations, point-of-sale equipment, small business phone systems,
audio/video equipment and home theater systems. Offers 4.5 minutes battery runtime with a full load of
1500VA and 13 minutes with a half load of 750VA. Supports hot-swappable battery replacement via built-
in access panel. Extended runtime available with optional BP24V15RT2U or BP24V28-2U external battery
packs.
Features
OMNIVSINT1500XL Uninterruptible Power Supply offers voltage regulation, surge suppression and long
lasting battery support
Supports entry level PCs up to 75 minutes during blackouts to enable shutdown without data loss,
runtime is further expandable by connecting an external battery pack
Highlights
1500VA / 1.5kVA tower 230V
line interactive extended-run
UPS
Corrects brownouts and
overvoltages from 151 to 282V
USB port, TEL/DSL/ethernet
protection, External battery pack
options
C14 input and 8 C13 outlets
Package Includes
OMNIVSINT1500XL line
interactive UPS
2 C13 to C14 interconnection
cables
USB and phone line cables
Owner's manual with warranty
information
1 / 5
Specifications
Regulates brownouts as low as 151 and overvoltages to 282V back to usable 230V nominal levels
without using battery power
8 IEC320 C13 outlets with complete AC surge suppression
C14 inlet accepts user-supplied AC power cord with country-specific plug
USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software,
available via FREE download from www.tripplite.com/poweralert
Dataline surge suppression protects standard dialup/DSL or Ethernet line connection
Audible alarm and 4 front panel LEDs offer complete UPS and line power status information
1500VA power handling ability supports a variety of sensitive electronic equipment
4.5 minutes full load runtime (1500VA), 13 minutes half load runtime (750VA)
Runtime is further expandable with the addition of external battery packs
Supports hot swappable battery replacement via built-in access panel
Optional PDUBHV10 bypass PDU enables hot-swappable UPS replacement with no disruption to
connected equipment
Attractive full color retail packaging
OVERVIEW
UPC Code 037332119780
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output kVA Capacity (kVA) 1.5
Output Watt Capacity (Watts) 940
Nominal Output Voltage(s)
Supported
220V; 230V; 240V
Nominal Voltage Details 230V nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line
Mode)
-18%, +8%
Output Voltage Regulation (Battery
Mode)
+/- 5%
Output Receptacles (8) C13
Included Output Power Cables Includes 2 C13 to C14 output power cables
Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets)
Output AC Waveform (AC Mode) Sine wave
2 / 5
Output AC Waveform (Battery
Mode)
PWM sine wave
INPUT
Rated input current (Maximum Load) 5A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Connection Description Attached 15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC power cord with country-specific
plug.
UPS Input Cord Length (ft.) 0.5
UPS Input Cord Length (m) 0.2
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4.5 min. (940w)
Half Load Runtime (min.) 13 min. (470w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility &nbsp;<a class="productLink" href="//www.tripplite.com/External-24V-2U-Rack-Tower-Battery-Pack-for-select-Tripp-
Lite-UPS-Systems-BP24V15RT2U~BP24V15RT2U">BP24V15RT2U</a>&nbsp;(limit 1); &nbsp;<a
class="productLink" href="//www.tripplite.com/External-24V-2U-Rack-Tower-Battery-Pack-select-Tripp-Lite-UPS-
Systems-BP24V28-2U~BP24V28-2U">BP24V28-2U</a>&nbsp;(limit 1); &nbsp;<a class="productLink"
href="//www.tripplite.com/External-24V-3U-Rack-Tower-Battery-Pack-select-Tripp-Lite-UPS-Systems-BP24V70-
3U~BP24V70-3U">BP24V70-3U</a>&nbsp;(multi-pack compatible)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included
Batteries)
Less than 4.5 hours from 10% to 90%
Internal UPS Replacement Battery
Cartridge
&nbsp;<a class="productLink" href="//www.tripplite.com/UPS-Replacement-Battery-Cartridge-Tripp-Lite-APC-Belkin-
Best-Powerware-Liebert-other-UPS~RBC51">RBC51</a>&nbsp;(quantity 2)
Battery Access Battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282
Overvoltage Correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage Correction Input voltages between 177 and 199 are boosted by 14%
Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-
battery status
3 / 5

OMNIVSINT1500XL

Mfr. #:
Manufacturer:
Tripp Lite
Description:
UPS - Uninterruptible Power Supplies 1500VA 940W UPS International Battery Back Up Tower AVR 230V C13
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet