Description
Tripp Lite's OMNI1000ISO offers complete UPS protection with built-in line-interactive voltage regulation,
intelligent monitoring and unattended shutdown capability. Built-in isolation transformer with Faraday
shield offers full isolation and complete common mode noise rejection. 1000VA power-handling capacity
supports point-of-sale applications, computers, internetworking equipment and home theater systems
during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 81V
and overvoltages as high as 143V back to normal 120V levels, reserving battery power for use during
complete power failures. USB communications port works with PowerAlert Software and cabling to
provide automatic unattended shutdown of connected network and PC applications.
Features
1000VA line-interactive UPS with Faraday-shielded, low-impedance isolation transformer delivers full
isolation from potential damage and performance problems
Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal-
reference ground, reducing data errors and audio/video distortion
Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working
through low voltage (brownouts) as low as 81V and overvoltages as high as 143V without consuming
battery power
Supports loads up to 1000VA/700W
Half-load runtime of 24 min. (500VA/350W); full load runtime of 8 min. (1000VA/700W)
5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery
low/replace
Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
Highlights
1000VA / 1kVA tower 120V line
interactive UPS with isolation
transformer
Corrects brownouts and
overvoltages from 81V to 143V
USB port, Normal & common
mode EMI/RFI line noise
immunity
NEMA 5-15P input plug and 6 5-
15R outlets
Package Includes
OMNI1000ISO UPS System
USB cable
Instruction manual
1 / 5
Specifications
USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software,
available via FREE download from www.tripplite.com/poweralert
Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance U.S., Canada, and Puerto
Rico only) safeguards connected equipment against damage
SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp
100Khz Ringwave and category B BiWave
SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1
INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54
db L-N from 50Khz to 500 Khz
6 UPS-supported AC outlets; 6-ft. cord
Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to
connected equipment
OVERVIEW
UPC Code 037332126931
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1
Output Watt Capacity (Watts) 700
Nominal Output Voltage(s)
Supported
110V; 115V; 120V
Nominal Voltage Details 115v nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line
Mode)
-18%, +8%
Output Voltage Regulation (Battery
Mode)
+/- 5%
Output Receptacles (6) 5-15R
Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery
Mode)
PWM sine wave
INPUT
Rated input current (Maximum Load) 7.6A
Nominal Input Voltage(s) Supported 120V AC
2 / 5
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 8 min. (700w)
Half Load Runtime (min.) 24 min. (350w)
DC System Voltage (VDC) 36
Battery Recharge Rate (Included
Batteries)
Less than 4.5 hours from 10% to 90%
Internal UPS Replacement Battery
Cartridge
&nbsp;<a class="productLink" href="//www.tripplite.com/UPS-Replacement-Battery-Cartridge-Kit-select-Tripp-Lite-
Best-Powerware-Liebert-other-UPS~RBC53">RBC53</a>&nbsp;
Battery Access Battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime No
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
Overvoltage Correction Input voltages between 128 and 143V are reduced by 9%
Undervoltage Correction Input voltages between 96 and 107V are boosted by 10%
Severe Undervoltage Correction Input voltages between 85 and 95V are boosted by 20%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-
battery status
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 510
UPS AC Suppression Response
Time
Instantaneous
EMI / RFI AC Noise Suppression Yes
ISOLATION
Output Isolation Transformer Professional grade load isolation transformer
3 / 5

OMNI1000ISO

Mfr. #:
Manufacturer:
Tripp Lite
Description:
UPS - Uninterruptible Power Supplies FULL ISOLATION UPS 1000VA 120V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union