ADG633 Data Sheet
Rev. B | Page 6 of 16
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 4.
Parameter Rating
V
to V
1
13 V
V
to GND −0.3 V to +13 V
V
to GND +0.3 V to −6.5 V
Analog Inputs
2
V
− 0.3 V to V
+ 0.3 V
Digital Inputs
2
GND − 0.3 V to V
DD
+ 0.3 V or
10 mA, whichever occurs first
Peak Current, S or D 40 mA (pulsed at 1 ms, 10%
duty cycle maximum)
Continuous Current, S or D 20 mA
Operating Temperature Range −40°C to +125°C
Storage Temperature Range −65°C to +150°C
Junction Temperature 150°C
θ
Thermal Impedance
16-Lead TSSOP 150.4°C/W
16-Lead LFCSP, 4-Layer Board 70°C/W
Lead Soldering
Lead Temperature, Soldering
(10 sec)
300°C
IR Reflow, Peak Temperature
(<20 sec)
220°C
(Pb-Free) Soldering
Reflow, Peak Temperature 260(+0/−5)°C
Time at Peak Temperature 20 sec to 40 sec
ESD 4 kV
1
The device is fully specified at a ±5 V dual supply and at 5 V and 3.3 V single
supplies. It is possible to operate the ADG633 with unbalanced supplies or at
other voltage supplies ( ±2 V to ±6 V, and 2 V to 12 V); however, the switch
characteristics change. These changes include, but are not limited to: analog
signal range, on resistance, leakage, V
INL
, V
INH
, and switching times. The
optimal power-up sequence for the device is: ground, V
DD
, V
SS
, and then the
digital inputs, before applying the analog input signal.
2
Overvoltages at Ax,
EN
, S, or D are clamped by internal diodes. Limit current
to the maximum ratings given.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Only one absolute maximum rating can be applied at any one time.
ESD CAUTION