83894121

83894 metal interlock switches 83894121 / 83894131 3
-
pole Part number 83894121
Monitoring of moving guards for machines with a stopping time which is greater than the time taken to access the danger zone
Locked by removing the voltage, unlocked by applying voltage to the electromagnet
Metal bodies and heads
Heads have 4 possible positions at 90°
Positive opening contacts
Part numbers
Specifications
Type
Type of contacts
Action
83 894 121
83894121 / 83894131 3-
pole
NC+NO+NO (2NO break before make)
Slow action
Conforming to standards Products
IEC 947
-5-
1, EN 60 947
-5-
1, UL 508, CSA C22
-
2 no.14, JIS C4520 (See P.3/4)
Conforming to standards Machine assemblies
IEC 204
-
1, EN 60 204
-
1, EN 1088, EN 292O
Certifications
UL, CSA
Protective treatment in normal operation
"TC"
Temperature Use (°C)
-
25→+70
Storage temperature (
0
C)
-
40→+70
Vibration resistance according to IEC/EN 60068
-2-6
Schok resistance according to IEC 28-2-27
Degree of protection according to IEC 529 and IEC 947
-5-
1
IP 67
Cable entry
One threaded hole for cable gland 13
Assigned working characteristics
AC 15 B300 Ue = 240 V, Ie = 1.5 A or Ue = 120 V, Ie = 3 A DC 13 Q300 Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A
Assigned insulation voltage according to IEC 947
-5-1
Ui = 500 V
Assigned insulation voltage according to UL 508, CSA
C22
-2 no.14
Ui = 300 V
Assigned impulse voltage according to IEC 947
-5-1
Uimp = 4 KV
Thermal rating according to IEC 947
-5-1
Ithe = 6 A
Electric shock protection Class 2 according to IEC 536
Resistance between terminals according to IEC 954-5-4
≤30m
Ω
Protection against short circuits
Cartridge fuse 10 A gG (gl)
Connection Screw clamp terminals
Clamping capacity with or without ferrule
min. 1 x 0,5 mm
2
,
max. 1,5 mm
2
Electrical life according to IEC 947
-5-
1 appendix C
Electromagnet supply voltage (50/60 Hz in AC)
120 V AC / DC
Maximum actuation speed
0,5 m/s
Minimum actuation speed
0,01 m/s
Resistance to removal of key
2000 N
Mechanical life (operating cycles)
10
6
Minimun operating frequency (operating cycles per hour)
600
Minimum positive opening force
20 N
Cable entry according to NFC 68 300
2 PG 13
Weight (g)
1140
Operating factor
100 %
Voltage limits
-20 % < +10 %
Service life
20 000
Consumption Inrush
10 VA
Consumption Sealed
10 VA
Assigned insulation voltage according to IEC 947
-5-1
250 V
Current consumption (mA)
7 mA
Assigned working voltage AC or DC
110 V / 240 V
Voltage limits AC or DC (including ripple)
95...264 V
Service life (h)
100 000
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
Accessories
Type 83 894 1 safety switches are fitted with an electromagnet for locking/unlocking the guard.
With the guard locked, the force required to remove the key is
200 daN.
In addition to the 3
-pole contact element actuated by the key, 83 894 2 limit switches also have a positive break type
"NC + NO" contact
element,
actuated by the electromagnet.
The "NC" contact is integrated in the machine safety circuit, and the "NO" contact indicates the position of the electromagnet.
Protection against voltage surges
Symbol
Accessories
Code
Straight key
79 214 578
Wide key
79 214 579
Flexible key
79 214 580
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
Type 83 894 1 safety switches are supplied with a key-operated lock which can be used to unlock the moving guard, bypassing the electromagnet.
Unlocking using a key
-operated lock is recommended in the following cases :
machine maintenance (if the key is turned to "UNLOCK" and then removed, this will prevent the machine from restarting accidentally, therefore ensuring the safety of maintenance personnel).
mains failure
problem with unlocking (locking cannot be released : fail-safe condition). Unlocking by applying voltage to the electromagnet always takes priority over unlocking using a key-operated lock.
The locking mechanism for standard devices allows the key to be removed in the "LOCK" and "UNLOCK" positions.
Power supply for the electromagnet on 83 894 1
The electromagnet for type 83 894 1 safety switches runs on D.C. and is therefore particularly reliable.
As it is protected by a bridge rectifier A.C. or D.C. supplies can be used (24 V, 48 V, 120 V or 230 V).
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com

83894121

Mfr. #:
Manufacturer:
Description:
Limit Switches KEY LOCK METAL SOLENOID110AC/DC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet