VOM618A
www.vishay.com
Vishay Semiconductors
Rev. 1.3, 10-Dec-12
4
Document Number: 83449
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 2 - Test Circuit Fig. 3 - Test Circuit and Waveforms
Note
• As per DIN EN 60747-5-5 (VDE 0884), § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings.
Compliance with the safety ratings shall be ensured by means of protective circuits.
TYPICAL CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
Fig. 4 - Forward Voltage vs. Forward Current Fig. 5 - Collector Current vs. Collector Emitter Voltage
(non-saturated)
Input
V
OUT
V
CC
= 5 V
R
L
10 %
90 %
Input pulse
Output pulse
t
r
t
on
t
f
t
off
SAFETY AND INSULATION RATINGS
PARAMETER SYMBOL VALUE UNIT
MAXIMUM SAFETY RATINGS
Output safety power P
SO
300 mW
Input safety current I
si
200 mW
Safety temperature T
S
150 °C
Comparative tracking index CTI 175
INSULATION RATED PARAMETERS
Maximum withstanding isolation voltage V
ISO
3750 V
RMS
Maximum transient isolation voltage V
IOTM
6000 V
peak
Maximum repetitive peak isolation voltage V
IORM
565 V
peak
Insulation resistance T
amb
= 25 °C, V
DC
= 500 V R
IO
10
12
Ω
Isolation resistance T
amb
= 100 °C, V
DC
= 500 V R
IO
10
11
Ω
Climatic classification (according to IEC 68 part 1) 55/110/21
Environment (pollution degree in accordance to DIN VDE 0109) 2
Internal creepage ≥ 5 mm
External creepage ≥ 5 mm
Clearance ≥ 5 mm
Insulation thickness ≥ 0.4 mm
0.1
1
10
100
0.6 0.8 1.0 1.2 1.4 1.6
I
F
- Forward Current (mA)
V
F
- Forward Voltage (V)
T
amb
= 110 °C
T
amb
= 75 °C
T
amb
= 25 °C
T
amb
= 0 °C
T
amb
= - 55 °C
0
10
20
30
40
50
0 1 2 3 4 5 6 7 8 9 10
I
C
- Collector Current (mA)
V
CE
- Collector Emitter Voltage (non-sat) (V)
I
F
= 1 mA
I
F
= 10 mA
I
F
= 5 mA
I
F
= 15 mA
I
F
= 20 mA
I
F
= 25 mA