AVQ100-36S3V3 DC-DC Converter 4/15
http://www.emersonnetworkpower.com.cn
Electrical Characteristics (Continued)
Parameter Min. Typ. Max. Unit Notes & Conditions
Isolation characteristics
Isolation voltage (conditions:
1mA for 60s, slew rate of
1500V/10s)
1500 V
Basic insulation, pollution degree 2,
input to output
1500 V
Basic insulation, pollution degree 2,
input to baseplate
1500 V
Basic insulation, pollution degree 2,
output to baseplate
Feature characteristics
Switching frequency 295 300 305 kHz
Remote
ON/OFF
control
(positive logic)
Off-state
voltage
-0.7 1.2 V
See Figure 11
On-state
voltage
3.5 12 V
Remote
ON/OFF
control
(negative
logic)
Off-state
voltage
3.5 12 V
On-state
voltage
-0.7 1.2 V
Output voltage trim range 2.64 3.63 V
See
Trim Characteristics
of
Application Note
Output voltage remote sense
range
0.3 V
Output over-voltage
protection
3.8 4.2 5 V
Hiccup: auto-restart when
over-voltage condition is removed
Over-temperature shutdown 125 °C
Auto recovery;over-temperature
protect(OTP) test point: see Figure 16
Over-temperature hysteresis 5 °C
Reliability characteristics
Calculated MTBF (telcordia ) 2.5 10
6
h
Telcordia SR-332-2006; 80% load,
300LFM, 40°C T
a
AVQ100-36S3V3 DC-DC Converter 5/15
http://www.emersonnetworkpower.com.cn
Electromagnetic compatibility requirements
Test Item Regulations Criteria Notes & Conditions
Conducted Emission
EN 55022
DC input port, Class A Limits
/
See EMC test conditions
Immunity to Electrostatic
Discharge
IEC/EN61000-4-2
Enclosure Port, Level 3
B
Immunity to Electrical Fast
Transient
IEC/EN61000-4-4
DC input port, Level 3
B
Immunity to Surges
IEC/EN61000-4-5
DC input port
Line to Ground(earth): 600V
Line to Line: 600V
B
Immunity to Continuous
Conducted Interference
IEC/EN61000-4-6
DC input port, Level 2
A
Immunity To Voltage Dips and
short interruptions and voltage
variations
EN 61000-4-29
DC input port
B
Criterion A: Normal performance during and after test.
Criterion B: For EFT and surges, low-voltage protection or reset is not allowed. Temporary output
voltage fluctuation ceases after disturbances ceases, and from which the EUT recovers its normal
performance automatically.
For Dips and ESD, output voltage fluctuation or reset is allowed during the test, but recovers to its
normal performance automatically after the disturbance ceases.
Criterion C: Temporary loss of output, the correction of which requires operator intervention.
Criterion D: Loss of output which is not recoverable, owing to damage to hardware.
AVQ100-36S3V3 DC-DC Converter 6/15
http://www.emersonnetworkpower.com.cn
Qualification Testing
Parameter Unit (pcs) Test condition
Halt test 4 ~ 5 T
a,min
-10°C to T
a,max
+10°C, 5°C step, V
in
= min to max, 0 ~ 105% load
Vibration 3
Frequency range: 5Hz ~ 20Hz, 20Hz ~ 200Hz, A.S.D: 1.0m
2
/s
3
, -3db/oct,
axes of vibration: X/Y/Z
Time: 30min/axis
Mechanical shock 3 30g, 6ms, 3axes, 6directions, 3time/direction
Thermal shock 3 -40°C to 100°C, unit temperature 20cycles
Thermal cycling 3 -40°C to 55°C, temperature change rate: 1°C/min, cycles: 2cycles
Humidity 3 40°C, 95%RH, 48h
Solder ability 15 IPC J-STD-002C-2007
Characteristic Curves
60
65
70
75
80
85
90
95
2.5 5 7.5 10 12.5 15 17.5 20 22.5 25
Output current (A)
Efficiency (%)
Vin=24V
Vin=48V
Vin=60V
Figure 1 Efficiency vs. Output current, T
a
=25°C, V
o
=3.3V
Figure 2 Output ripple & noise (2µs/div, 20mV/div),
see Figure 14 for test configuration
Figure 3 Input reflected ripple current (2µs/div,
5mA/div), see Figure 14 for test configuration

AVQ100-36S3V3-6L

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters 82.5W 18-60Vin Sngl 3.3V 25A Neg Logic
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS