SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
Note.6
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
50ms/230VAC 10ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
1.1A/115VAC 0.65A/230VAC
COLD START 45A
<2mA / 240VAC
110 ~ 150% rated output power
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
-20 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
413.3K hrs min. MIL-HDBK-217F (25 )℃
129*98*38mm (L*W*H)
File Name:NED-50-SPEC 2012-09-24
OVER VOLTAGE
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
50W Dual Output Switching Power Supply
•
Universal AC input / Full range
•Protections: Short circuit / Overload / Over voltage
•Cooling by free air convection
•100% full load burn-in test
•2 years warranty
■
Features :
NED-50 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 7)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
NED-50A
5V
6A
1 ~ 6A
54W
80mVp-p
CH1: 4.75 ~ 5.5V
±2.0%
±0.5%
±1.5%
CH1: 5.75 ~ 6.75V
79%
NED-50B
12V
CH2
24V
CH2
5V
CH1
2A 1.4A4A
0.3 ~ 3A 0.2 ~ 2A1 ~ 6A
53.6W
120mVp-p 200mVp-p80mVp-p
CH1: 4.75 ~ 5.5V
±6.0% ±6.0%
±1.0% ±1.0%
±3.0% ±3.0%
±2.0%
±0.5%
±1.5%
82%
LINE REGULATION
Note.4
LOAD REGULATION Note.5
CH1OUTPUT NUMBER
0.44Kg; 30pcs/14.2Kg/0.72CUFT
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, CB(IEC60950-1) approved
EMC IMMUNITY
EMC EMISSION