DocID027541 Rev 1 9/20
L9915B Electrical specification
19
3.3 Electrical characteristics
3.3.1 Pin “B”
Table 6. Electrical characteristics - Pin “B”
Symbol Parameter Test condition Min Typ Max Unit
VB
OVR
Operating voltage range - 6 - 18 V
IB
stby
Standby current
consumption
VB = 12.5 V; VPH = 0; VL = 0 V;
C pin floating; T = -40 °C
250 - 350 μA
IB
stby
Standby current
consumption
200 - 300 μA
IB
stby
Standby current
consumption
VB = 12.5 V; VPH = 0; VL = 0 V;
C pin floating; T = 130 °C
150 - 250 μA
VB
ISP
Internal mode set-point
voltage
VPH = 10 Vpp square wave; L pin
connected to B pin with 100 Ω;
C floating @ T
j
= 30 °C
F duty cycle = 15%
14.37 14.55 14.73 V
VB
ITD
Internal thermal drift - -5 -7 -9 mV/°C
VB
ESP
External mode
set-point voltage
VPH = 10 Vpp square wave; L pin
connected to B pin with 100 Ω;
C 73% PWM duty cycle @
T
j
= 30 °C; F duty cycle = 15%
14.37 14.55 14.73 V
VB
ESP10
External mode
set-point voltage
(duty cycle on C = 10%)
VPH = 10 Vpp square wave; L pin
connected to B pin with 100 Ω;
C 10 % PWM duty cycle @
T
j
= 30°C; F duty cycle = 15 %
11.5 11.7 11.9 V
VB
ESP90
External mode
set-point voltage
(duty cycle on C = 90%)
VPH=10 Vpp square wave; L pin
connected to B pin with 100 Ω;
C 90 % PWM duty cycle @
T
j
= 30 °C; F duty cycle = 15 %
15.1 15.3 15.5 V
VB
ETD
External thermal drift - -1 0 1 mV/°C
VB
DESP
Default external mode
set-point voltage
VPH=10Vpp square wave; L pin
connected to B pin with 100 Ω;
C <2% or >98% PWM duty cycle
@ T
j
= 30 °C; F duty cycle = 15 %
14.37 14.55 14.73 V
VB
DETD
Default external thermal drift - -1 0 1 mV/°C
ΔVB
load
Regulated voltage variation
with the load (for both
int./ext. regulation)
Difference between regulated
voltage when F duty cycle is 5%
and regulated voltage when F duty
cycle is 95%
- - 300 mV
VB
wb
Regulation without battery N. A. 10 - 16 V
VB
IntOvp
Internal mode over-voltage
protections threshold
Without ECU communication 15.5 16.2 16.9 V
VB
ExtOvp
External mode over-voltage
protections threshold
With ECU communication 16.5 17.2 17.9 V