1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Specifications and characteristics in brief
Rated voltage V
R
Surge voltage V
S
350 ... 450 V DC
1.1 V
R
Rated capacitance C
R
Capacitance tolerance
560 ... 5300 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
≤ 0.20
Leakage current I
leak
(20 °C, 5 min)
Self-inductance ESL d = 64.3 mm: approx. 14 nH
d ≥ 76.9 mm: approx. 18 nH
Capacitors with low-inductance design:
d ≥ 76.9 mm: approx. 13 nH
Useful life
1)
Requirements:
105 °C; V
R
; I
AC,R
> 8000 h ∆C/C ≤ ±15% of initial value
85 °C; V
R
; I
AC,R
> 40000 h tan δ ≤ 1.75 times initial specified limit
40 °C; V
R
; 3 I
AC,R
> 250000 h I
leak
≤ initial specified limit
Voltage endurance test Post test requirements:
105 °C, V
R
; I
AC,R
2000 h ∆C/C ≤ ±10% of initial value
tan δ ≤ 1.3 times initial specified limit
I
leak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
Characteristics at low
temperature
Max. impedance ratio
Z
-25
°
C
/ Z
20
°
C
4
at 100 Hz Z
-40
°
C
/ Z
20
°
C
10
IEC climatic category To IEC 60068-1:
40/105/56 (40 °C/+105 °C/56 days damp heat test)
Sectional specification IEC 60384-4
B43750, B43770
Extremely high ripple current 105 °C
Page 3 of 16Please read Cautions and warnings and
Important notes at the end of this document.