WITHSTAND VOLTAGE
ISOLATION RESISTANCE
CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
OUTPUT
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
0.8A / 347VAC 0.6A / 480VAC
<0.75mA / 480VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to FCC Part 15 Subpart B,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level surge immunity Line-Earth 4KV, Line-Line 2KV , EAC TP TC 020()
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
℃
±℃ ℃
0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 (type”HL”), CSA C22.2 No. 250.13-12, EAC TP TC 004 IP65 or IP67 approved,
114.5K hrs min. MIL-HDBK-217F (25 )℃
254.2*68*38.8mm (L*W*H)
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
92.5%
92.5%
93%
92.5%
93% 93%
±1.0%
5 ~ 10A
±1.0%
4 ~ 8A
±
1.0%
3.3 ~ 6.7A
±
1.0%
2.5 ~ 5A
±
0.5% ±0.5%
±0.5%
±0.5%
±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
2.25 ~ 4.5A
±
0.5%
±0.5%
±1.0%
2.85 ~ 5.7A
±
0.5%
±0.5%
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
54V
27 ~ 54V
42V
21 ~ 42V
EMC IMMUNITY
EMC EMISSION
COLD START 50A(t =532 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
240W Constant Voltage + Constant Current LED Driver
HVG-240 series
HVG-240-24 HVG-240-30 HVG-240-36 HVG-240-42 HVG-240-48 HVG-240-54
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
12ms/347VAC, 480VAC
500ms, 150ms /230VAC, 347VAC, 480VAC
180 ~ 528VAC 254VDC ~ 747VDC
Shut down and latch off o/p voltage, re-power on to recover
Shut down and latch off o/p voltage, re-power on to recover
RATED CURRENT
RATED POWER
VOLTAGE ADJ. RANGE
RIPPLE & NOISE (max.)
Note.2
10A
8A
6.7A
5A
240W 240W
241.2W
240W
150mVp-p
22.4 ~ 25.6V
200mVp-p
28 ~ 32V
250mVp-p
33.5 ~ 38.5V
250mVp-p
44.8 ~ 51.2V
4.5A
243W
350mVp-p
50 ~ 57V
5.7A
239.4W
250mVp-p
39 ~ 45V
27 ~ 34V
33 ~ 39V
43 ~ 49V 55 ~ 63V
48 ~ 54V 60 ~ 67V
Adjustable for A/AB-Type only (via the built-in potentiometer)
Adjustable for A/AB-Type only (via the built-in potentiometer)
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.98/230VAC, PF 0.97/277VAC, PF 0.95/347VAC, PF 0.93/480VAC @full load≧≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@ load 50%/230VAC, 277VAC, 347VAC, @ load 60%/480VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC
WORKING TEMP.
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP.
Tcase=+90℃
PACKING
1.31Kg; 12pcs/15.7Kg/0.78CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.
Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7.
The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:HVG-240-SPEC 2018-05-29