Data Sheet ADuM3480/ADuM3481/ADuM3482
Rev. A | Page 9 of 20
PACKAGE CHARACTERISTICS
Table 10.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input-to-Output)
1
R
I-O
10
12
Ω
Capacitance (Input-to-Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance
JC
Thermocouple located at center of package underside,
test conducted on 4-layer board with thin traces
1
The device is considered a 2-terminal device: Pin 1 to Pin 10 are shorted together; Pin 11 to Pin 20 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM3480/ADuM3481/ADuM3482 are approved by the organizations listed in Table 11. See Table 16 and the Insulation Lifetime
section for the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
REGULATORY APPROVALS
Table 11.
UL CSA VDE
Recognized under the UL 1577
component recognition program
1
Approved under CSA Component
Acceptance Notice #5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single protection, 3750 V rms
isolation voltage
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage
Reinforced insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM3480/ADuM3481/ADuM3482 is proof tested by applying an insulation test voltage of ≥4500 V rms for 1 second (current
leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each of the ADuM348x is proof tested by applying an insulation test voltage of ≥1050 V peak for 1 second (partial discharge
detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 12.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 3750 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) >5.1 mm Measured from input terminals to output terminals,
shortest distance through air, in the plane of the PCB
Minimum External Tracking (Creepage)
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)