3
SSGSSG
■ Characteristics
Note: 1. The data given above are initial values.
2. For testing conditions, consult your OMRON sales representative.
■
Approved Standards
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No. 55 (File No. LR21642)
EN61058-1 (File No. T9451449, TÜV Rheinland approval)
Testing conditions: 5E4 (50,000 operations), T125 (0°C to 125°C)
■
Contact Specifications
Note: For more information on the minimum applicable load, refer to Using Micro Loads on page 8.
Operating speed 0.1 mm to 1 m/s (pin plunger models)
Operating frequency Mechanical: 400 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min.
Contact resistance OF 1.50 N: SSG-5 models: 30 mΩ max.
SSG-01 models: 50 mΩ max.
OF 0.50 N: SSG-5 models: 50 mΩ max.
SSG-01 models: 100 mΩ max.
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between contacts of the same polarity
(600 VAC for SSG-01H and SSG-01T models)
1,500 VAC, 50/60 Hz for 1 min between each terminal and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Vibration resistance
Malfunction: 10 to 2,000 Hz, 196 m/s
2
{20G} (Contact open: 10 µs max., lever position: at TTP)
Shock resistance
Malfunction: 490 m/s
2
{approx. 50G} (Contact open: 10 µs max., lever position: at TTP)
Durability (see note 2) Mechanical: 10,000,000 operations min. (60 operations/min)
Electrical: 200,000 operations min. (30 operations/min)
Degree of protection (IP code) IEC IP40
Degree of protection against
electrical shock
Class I
Proof tracking index 175
Ambient operating temperature –25°C to 125°C (at ambient humidity of 60% max.) (with no icing or condensation)
Ambient operating humidity 85% max. (5°C to 30°C)
Weight Approx. 1.6 g (pin plunger models)
Rated voltage SSG-5 SSG-01
125 VAC 5 A 0.1 A
250 VAC 3 A ---
30 VDC --- 0.1 A
Rated voltage SSG-5 SSG-01
250 VAC 5 A ---
30 VDC --- 0.1 A
Item SSG-5 SSG-01H.T SSG-01P
Contact Specification Rivet Crossbar Crossbar
Material Silver Gold alloy Gold alloy
Gap (standard value) 0.5 mm 0.25 mm 0.5 mm
Inrush current NC 20 A max. 1 A max. 1 A max.
NO 10 A max. 1 A max. 1 A max.
Minimum applicable load (see note) 160 mA at 5 VDC 1 mA at 5 VDC 1 mA at 5 VDC