DIN rail power supply unit 15 V DC/4 A, primary switched-mode, 1-
phase
Commercial data
GTIN (EAN) 4046356308540
sales group H012
Pack 1 pcs.
Customs tariff 85044081
Weight/Piece 0.309 KG
Catalog page information Page 585 (IF-2009)
Product notes
WEEE/RoHS-compliant since:
03/06/2008
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Product description
STEP POWER power supply units – for building automation
The new STEP POWER generation of compact power supply units is particularly suitable for installation distributors
and flat control panels thanks to its design. The power supply units are available with 24VDC output voltage in various
performance classes and widths and with the special voltages 5, 12, 15 and 48VDC. Their high degree of efficiency and
the low standby losses make for high power efficiency.
STEP-PS/ 1AC/15DC/4 Order No.: 2868619
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2868619
PHOENIX CONTACT Inc., USA Page 2 / 6
http://www.phoenixcon.com Oct 8, 2010
Technical data
Input data
Nominal input voltage 100 V AC ... 240 V AC
AC input voltage range 85 V AC ... 264 V AC
DC input voltage range 95 V DC ... 250 V DC
AC frequency range 45 Hz ... 65 Hz
DC frequency range 0 Hz
Current consumption Approx. 0.8 A (120 V AC)
Approx. 0.5 A (230 V AC)
Inrush surge current < 15 A (typical)
Power failure bypass > 27 ms (120 V AC)
> 120 ms (230 V AC)
Input fuse 3.15 A (slow-blow, internal)
Permissible backup fuse B6
B10
B16
Type of protection Transient surge protection
Protective circuit/component Varistor
Output data
Nominal output voltage 15 V DC ±1%
Setting range of the output voltage 10 V DC ... 16.5 V DC (> 15 V constant capacity)
Output current 4 A (-25°C ... 55°C)
4.4 A (-25 °C ... 40 °C permanent)
9 A (maximum output current)
Derating +55°C to +70°C: 2.5% per Kelvin
55 °C ... 70 °C 2.5%/K
Connection in parallel Yes, for redundancy and increased capacity
Connection in series Yes
Control deviation < 1 % (change in load, static 10% ... 90%)
< 2 % (change in load, dynamic 10% ... 90%)
< 0.1 % (change in input voltage ±10%)
Residual ripple < 55 mV
PP
(20 MHz)
Peak switching voltages nominal load < 10 mV
PP
(20 MHz)
Maximum power dissipation idling < 0.5 W
Power loss nominal load max. 8.6 W
STEP-PS/ 1AC/15DC/4 Order No.: 2868619
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2868619
PHOENIX CONTACT Inc., USA Page 3 / 6
http://www.phoenixcon.com Oct 8, 2010
General data
Width 72 mm
Height 90 mm
Depth 61 mm
Net weight 0.3 kg
Operating voltage display LED green
Efficiency > 87 % (for 230 V AC and nominal values)
Insulation voltage input/output 4 kV AC (type test)
2 kV AC (routine test)
Degree of protection IP20
Class of protection II
MTBF > 500 000 h in acc. with IEC 61709 (SN 29500)
MTBF (IEC 61709, SN 29500) > 500000 h
Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, no condensation)
Mounting position Horizontal DIN rail NS 35, EN 60715
Assembly instructions Can be aligned: Horizontal 0 cm, vertical 3 cm
Electromagnetic compatibility Conformance with EMC directive 2004/108/EC
Noise immunity EN 61000-6-2:2005
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard – Electrical equipment of machines EN 60204
Standard - Safety of transformers IEC 61558-2-17
Standard - Electrical safety IEC 60950/VDE 0805 (SELV)
Shipbuilding approval Germanischer Lloyd (EMC 1), ABS, NK
Standard – Electronic equipment for use in
electrical power installations and their assembly
into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950 (SELV) and EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
DIN VDE 0106-1010
Standard – Protection against electric shock DIN 57100-410
Standard – Protection against shock currents,
basic requirements for protective separation in
electrical equipment
DIN VDE 0106-101
Standard – Limitation of mains harmonic currents EN 61000-3-2