F1500CA03

Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
18
SINGLE PHASE FILTERS
F1500 RFI Filters
Nominal
Current
Rating
Part
Number
Termination
Line/Load
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
MODE
Frequency - MHz
.15 .50 1.0 5.0 10 30
3A
F1500AA03
F1500CA03
F1500FA03
F1500CB03
QC/QC
IEC/QC
Fused IEC/QC
QC/Wire
Common
Differential
32
35
43
60
50
65
50
60
50
55
50
40
6A
F1500AA06
F1500CA06
F1500FA06
F1500CB06
IEC/QC
Fused IEC/QC
QC/Wire
Common
Differential
32
30
42
60
45
65
45
65
45
60
45
50
10A
F1500AA10
F1500CA10
F1500FA10
F1500CB10
QC/QC
IEC/QC
Fused IEC/QC
Common
Differential
29
15
36
50
39
65
45
65
45
60
45
50
15A
F1500CA15
F1500CB15
IEC/QC
IEC/Wire
Common
Differential
26
35
32
60
36
65
44
65
46
65
52
65
Features:
• IEC Connector Plus
Common and Differential
Mode Performance in Compact Case
• “L” Circuit Configuration — Cost-Effective in Many
Linear and Switching Power Supply Applications
• High-Inductance Design for Greater Attenuation
• Available with 0.250" Quick Connect Terminals or
Wire Leads on the Load Side
F1500AX/F1500CX Simplied Schematic
Specications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current: 115VAC 250VAC
3A 1.5A
6A 3A
10A 6A
15A 8A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground 1500VAC
Line to Line 1768VDC
Insulation Resistance: 9 x 10
9
Ω at 100VDC
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
A: QC – Quick Connect
B: Wire
C: IEC Receptacle
F: IEC Receptacle with Fuse Holder
Maximum Leakage Current:
Each Line to Ground F1500
115VAC, 60Hz: 0.25mA
250VAC, 50Hz: 0.40mA
Agency Approvals:
LINE
L
G
N
LOAD
L
N
LOAD
L
N
LINE
L
G
N
NOTE: Other combinations of terminals may be specied on special order.
High Performance
F1500FX Simplied Schematic
Except Quick
Connect Termination
on Line Input
Curtis Industries
A Division of Powers Holdings, Inc.
1-800-657-0853
Dimensions are in inches and millimeters
unless otherwise specied.
Values in parentheses are metric equivalents.
19
SINGLE PHASE FILTERS
L
O
A
D
.250 QC
(6,4)
(2) No. 6-32 UNC2B
B
A D
C
L
I
N
E
(1) 5mm x 20mm Fuse (not included)
High Performance
Amps A B C D E
3A
3.31
(84,1)
2.000
(50,8)
1.13
(28,7)
2.938
(74,6)
2.50
(63,5)
10A
3.31
(84,1)
2.000
(50,8)
1.50
(38,1)
2.938
(74,6)
2.50
(63,5)
F1500AA (3 and 10Amp) Dimensions
Refer to Page 40
for Standard
Mounting Cutouts
L
I
N
E
L
O
A
D
E
A
C
D
.188 Dia.
(4,77)
2 Holes
B
F1500CA
(3, 6, 10 and 15Amp) Dimensions
F1500CB
(3, 6, 10 and 15Amp) Dimensions
Refer to Page 40
for Standard
Mounting Cutouts
F1500FA
(3, 6 and 10Amp) Dimensions
Refer to Page 40
for Standard
Mounting Cutouts
E
Amps A B C D E
3A
2.000
(50,8)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.752
(19,1)
6A
2.500
(63,5)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.752
(19,1)
10A
2.500
(63,5)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.752
(19,1)
L
I
N
E
L
O
A
D
E
A
D
.250 QC
(6,4)
B
(2) No. 6-32 UNC2B
C
Amps A B C D E
3A
2.000
(50,8)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.565
(14,3)
6A
2.500
(63,5)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.565
(14,3)
10A
2.500
(63,5)
2.000
(50,8)
1.500
(38,1)
.550
(14,0)
.565
(14,3)
15A
3.25
(82,6)
2.25
(57,2)
1.75
(44,5)
.550
(14,0)
.705
(17,9)
Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
40
SINGLE PHASE FILTERS
Standard Mounting Cutouts
F1200CA, F1300CA, F1400CA,
F1500CA, F1600CA, F1700CA
F1500FA, F1600FA,
1.145
(29,08)
1.417
(36,0)
1.275
(32,39)
.09 R
(2,29)
.638
(16,21)
.140 Dia.
(3,55)
2 Holes
1.20
(30.5)
.90
(22,9)
1.575
(40,0)
.187
(4,75)
.450
(11,43)
.234
(5,94)
.140 Dia.
(3,55)
2 Holes
F1300CP, F1600CP
.062 Hole Dia.
(1,57)
5 Holes
1.500
(38,1)
.600
(15,2)
.700
(17,8)
1.400
(35,6)
N
L
F5500/5600/5700 SERIES
.140 Dia.
(3,55)
2 Holes
.234 R.
(5,94)
(Typ.)
1.575
(40,01)
1.20
(30,48)
.90
(22,8)
for mounting
from back side
SERIES
PE = Power Entry
PM = Medical
Power Entry
LOAD
TERMINATION
A = Quick Connects
B = Wire Leads
D = Screw Terminals
(20 & 30 amp only)
P = Printed Circuit Pins
S = Solder Tab
LINE TERMINATION
A = Quick Connects
B = Wire Leads
C = IEC Connector
D = Screw Terminals
(20 & 30 amp only)
F = Fused IEC
P = Printed Circuit Pins
W = Dual Fused IEC
J = Switched IEC
How to Order
The Curtis part numbering system is made up of four
elements. Each element denotes a specic requirement
(mechanical or electrical) which, when properly
sequenced, fully identies the required catalog lter. As
shown, the rst ve alpha/numeric characters denote
the series type; the sixth character (alpha) denotes the
type of line termination; the seventh character (alpha)
denotes the type of load termination; the last two
characters (numeric) denote the current rating.
Compose your part number as follows: Select the series
required, add two alpha character for the line and load
termination, followed by two numeric characters for
the required current rating. For example, F1100AB06
completely identies an F1100 series lter with quick
connects on line side and wire leads on load side, with
a 6-amp rating.
F1100 X X X
CURRENT
RATING
01 = 1 Amp
03 = 3 Amps
06 = 6 Amps
10 = 10 Amps
15 = 15 Amps
20 = 20 Amps
30 = 30 Amps

F1500CA03

Mfr. #:
Manufacturer:
Description:
Power Line Filter 50Hz/60Hz 3A 250VAC Quick Connect Screw Mount