1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Specifications and characteristics in brief
Rated voltage V
R
Surge voltage V
S
16 ... 100 V DC
1.15 V
R
Rated capacitance C
R
Capacitance tolerance
1500 ... 220000 µF
10/+30% Q
Leakage current I
leak
(20 °C, 5 min)
Self-inductance ESL d = 35.7 mm: approx. 10 nH
d = 51.6 mm: approx. 15 nH
d ≥ 64.3 mm: approx. 20 nH
Useful life
1)
d ≤ 51.6 mm d ≥ 64.3 mm Requirements:
105 °C; V
R
; I
AC,R
> 10000 h > 20000 h ∆C/C ≤ ±45% of initial value
85 °C; V
R
; I
AC,max
> 15000 h > 25000 h ESR ≤ 3 times initial specified limit
40 °C; V
R
; 2.4 I
AC,R
> 200000 h I
leak
≤ initial specified limit
40 °C; V
R
; 2.7 I
AC,R
> 200000 h
Voltage endurance test Post test requirements:
105 °C; V
R
; I
AC,R
5000 h ∆C/C ≤ ±15% of initial value
ESR ≤ 1.3 times initial specified limit
I
leak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
IEC climatic category To IEC 60068-1:
55/105/56 (55 °C/+105 °C/56 days damp heat test)
Detail specification
Sectional specification
Similar to CECC 30301-804
IEC 60384-4
Ripple current capability
Due to the ripple current capability of the contact elements, the following current upper limits must
not be exceeded:
Capacitor diameter ≤ 51.6 mm > 51.6 mm
I
AC,max
30 A 40 A
B41550, B41570
SIKOREL 105 °C
Page 3 of 17Please read Cautions and warnings and
Important notes at the end of this document.