ORDERING INFORMATION
TYPES
1) Standard type
Standard packing: Carton 100 pcs., Case 500 pcs.
1a/1c 5A/10A small power
relays
JQ RELAYS
Nominal coil voltage
Standard type High capacity type
1 Form A 1 Form C 1 Form A 1 Form C
Part No. Part No. Part No. Part No.
5V DC JQ1a-5V-F JQ1-5V-F JQ1aP-5V-F JQ1P-5V-F
6V DC JQ1a-6V-F JQ1-6V-F JQ1aP-6V-F JQ1P-6V-F
9V DC JQ1a-9V-F JQ1-9V-F JQ1aP-9V-F JQ1P-9V-F
12V DC JQ1a-12V-F JQ1-12V-F JQ1aP-12V-F JQ1P-12V-F
18V DC JQ1a-18V-F JQ1-18V-F JQ1aP-18V-F JQ1P-18V-F
24V DC JQ1a-24V-F JQ1-24V-F JQ1aP-24V-F JQ1P-24V-F
48V DC JQ1-48V-F JQ1P-48V-F
VDE
RoHS compliant
FEATURES
• High electrical noise immunity
• High switching capacity in a compact
package
• High sensitivity: 200 mW (1a),
400 mW (1c)
• High surge voltage: 8,000 V between
contacts and coil
• UL, CSA, VDE, SEMKO approved and
TÜV available
• Class B coil insulation type also
available.
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
Contact arrangement
1a: 1 Form A
1 : 1 Form C
Contact capacity
Nil:
P:
Standard (5A)
High capacity (10A)
JQ F
Coil insulation class
Nil:
B:
Class E coil insulation
Class B coil insulation (UL)
Contact material
F: AgSnO2 type
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type
Partly to Be Discontinued:
10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
–2–
ASCTB185E 201509-T
RATING
1. Coil data
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
Contact
arrangement
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out
voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68
°F)
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
1 Form A
5V DC
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
(Initial)
40.0mA 125 Ω
200mW
180% of nominal voltage
(at 20°C 68°
F)
130% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
6V DC 33.3mA 180 Ω
9V DC 22.2mA 405 Ω
12V DC 16.7mA 720 Ω
18V DC 11.1mA 1,620 Ω
24V DC 8.3mA 2,880 Ω
1 Form C
5V DC
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
(Initial)
80 mA 62.5Ω
400mW
150% of nominal voltage
(at 20°C 68°F)
110% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
6V DC 66.7mA 90 Ω
9V DC 44.4mA 202.5Ω
12V DC 33.3mA 360 Ω
18V DC 22.2mA 810 Ω
24V DC 16.7mA 1,440 Ω
48V DC 8.3mA 5,760 Ω
Characteristics Item
Specifications
Standard type High capacity type
Contact
Arrangement 1 Form A 1 Form C 1 Form A 1 Form C
Contact resistance (Initial) Max. 100mΩ (By voltage drop 6 V DC 1 A)
Contact material AgSnO
2
type
Rating
Nominal switching capacity (resistive load)
5 A 125 V AC,
2 A 250 V AC,
5 A 30 V DC
N.O. side:
5 A 125 V AC,
2 A 250 V AC,
3 A 30 V AC
N.C. side:
2 A 125 V AC,
1 A 250 V AC,
1 A 30 V DC
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V DC
N.O. side:
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V AC
N.C. side:
3 A 125 V AC,
2 A 250 V AC,
1 A 30 V DC
Max. switching power (resistive load) 625 VA, 150 W
N.O. side:
625 VA, 90 W
N.C. side:
250 VA, 30 W
1,250 V AC, 150 W
N.O. side:
1,250 VA, 150 W
N.C. side:
500 V AC, 30 W
Max. switching voltage 250 V AC, 110 V DC (0.3A)
Max. switching current N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A
Nominal operating power 200 mW 400 mW 200 mW 400 mW
Min. switching capacity (reference value)*
1
100 mA, 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil)
Max. 45°C 113°F
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
5A, at 70°C 158°F)
Max. 45°C 113°F
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
10A, at 70°C 158°F)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
8,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 10 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
Shock resistance
Functional 294 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
Expected life Mechanical (at 180 times/min.) Min. 10
7
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F (class E insulation),
–40°C to +85°C –40°F to +185°F*
4
(class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 7 g .25 oz
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
–3–
ASCTB185E 201509-T
3. Expected electrical life
REFERENCE DATA
Standard type
Type Switching capacity No. of operations
Standard type
1 Form A
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5×10
4
2×10
5
2×10
5
10
5
1 Form C
N.O.
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
5×10
4
2×10
5
2×10
5
10
5
N.C.
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
High capacity type
1 Form A
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
1 Form C
N.O.
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
1.-(1) Max. switching capacity (1 Form A type) 1.-(2) Max. switching capacity (1 Form C type)
AC resistive load (High capacity type)
AC resistive load (Standard type)
1
10 100 250 1,000
10
100
5
Contact voltage, V
Contact current, A
1
10 100 250 1,000
10
100
2
3
5
Contact voltage, V
Contact current, A
AC resistive load
(High capacity type) N.O. side
AC resistive load
(High capacity type)
N.C. side
AC resistive load
(Standard type) N.O. side
AC resistive load
(Standard type)
N.C. side
2. Life curve
Ambient temperature: room temperature
3.-(1) Operate & release time (1 Form A type)
Tested sample: JQ1a-12V-F, 25 pcs.
3.-(2) Operate & release time (1 Form C type)
Tested sample: JQ1-24V-F, 25 pcs.
100
10
1
102345
Contact current, A
Life, ×10
4
125V AC
resistive load
250V AC
resistive load
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
Max.
Min.
Min.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016

JQ1P-12V

Mfr. #:
Manufacturer:
Panasonic
Description:
RELAY GEN PURPOSE SPDT 10A 12V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union