TU425S24E

TU425
425W Single Output
Test and Measurement/Industrial Series
www.slpower.com TU425 REV 2.8 29-MAY-15 1
Features
3.3” x 6.2” x 1.62” Package
Up to 425W of Air-Cooled Power, 300W Convection
Universal Input 90-264Vac Input Range
5V at 2A Isolated Standby Output
Isolated 12V Fan Output
Inhibit, Power Fail, DC OK Signals, Remote Sense
Approved to CSA/EN/IEC/UL60950-1, 2
nd
Edition
Compliant to high levels of EMC per EN61000-4
Meets Class B Conducted EMI with 6db margin,
Class A Radiated EMI with 3db margin
Efficiency 90% typical
3 Year Warranty
Description
A Superior performance 425 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature
rich and highly efficient TU425 product family with active current share for redundant applications can easily fit in 1U chassis and
provides 300 Watts for convection or 425 Watts with moving air. Input & output monitoring alarms plus isolated 12V/1A fan output
and 5V/2A standby voltage are among other standard offering of TU425 family. All models are CE marked to low voltage directive
and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition.
Model Selection
Model
Output Current
Efficiency³
Ripple & Noise
4
Total
OVP
Number
Volts
¹
Convection
²
(Main Output)
(mV pk
-
pk)
Regulation
Threshold
MTBF
7
TU425S12E
12V
5Vsb
12V Fan
5
32.2A
2.0A
1.0A
22.0A
2.0A
0.5A
88%
120mV
100mV
360mV
±
3%
±5%
±10%
14.0 ± 1.1V
5.5V – 8.0V
N/A
389,750
TU425S18E
18V
5Vsb
12V Fan
5
21.4A
2.0A
1.0A
14.6A
2.0A
0.5A
88%
180mV
100mV
360mV
±
3%
±5%
±10%
21.0 ± 2.0V
5.5V – 8.0V
N/A
356,330
TU425S24E
24V
5Vsb
12V Fan
5
16.8A
2.0A
1.0A
11.9A
2.0A
0.5A
90%
240mV
100mV
360mV
±
3%
±5%
±10%
28.0 ± 2.5V
5.5V – 8.0V
N/A
355,520
TU425S48E
48V
5Vsb
12V Fan
5
8.4A
2.0A
1.0A
5.9A
2.0A
0.5A
90%
480mV
100mV
360mV
±
3%
±5%
±10%
55.0 ± 4.0V
5.5V – 8.0V
N/A
354,722
TU425S56E
56V³
5Vsb
12V Fan
5
7.2A
2.0A
1.0A
5.1A
2.0A
0.5A
90%
560mV
100mV
360mV
±
3%
±5%
±10%
63.0 ± 4.0V
5.5V – 8.0V
N/A
354,560
Notes:
1. Total power with 200lfm of forced air cooling is 425W (385W for 12V model) including 12V/1A for Fan output and 5V/2A standby.
2. Maximum convection cooled power is limited to 280W for 12V model and 300W for other models. This includes 12V/0.5A fan output and 5V/2A standby output.
3. Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
4. Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
5. Fan Output: If the load on this output is other than a fan, a short circuit condition on this output can only be remedied by removing both the cause of the short circuit and the
load. This will allow the output to resume normal operation.
6. No output adjustment for 56V model.
7. MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input.
TU425
425W Single Output
Test and Measurement/Industrial Series
www.slpower.com TU425 REV 2.8 29-MAY-15 2
General Specifications
AC Input
100-240Vac, ±10%, 47-63Hz, 1
120–300Vdc (external fuse required for DC input)
Turn On Time
(Main Output)
Main output: <1 sec. max @115Vac, rise time 30mS
max. 5Vsb turn-on time is 500mS max., rise time
50mS max. Output Voltage rise is monotonic.
Input Current
115Vac: 5.2A, 230Vac: 2.5A
Hold-up Time
Main Output: >20ms for 300W @ 120Vac/60 Hz,
>16ms for 383W (90% of 425W) @ 120v/60Hz.
5Vsb Output: >500mS
Inrush Current
264Vac, cold start: will not exceed 40Arms
within ½ cycle. I²T = 25A²/Sec maximum
Overtemperature
Protection
Sensing transformer temperature, 135°C (55°C
ambient temperature at full load), auto recovery.
Input Fuses
F1, F2: 6.3A, 250Vac
Overload Protection
130 to 170% of rating, Hiccup Mode, auto recovery.
Earth Leakage
Current
<750μA@264Vac, 60Hz, NC
<1.5mA@264Vac, 60Hz, SFC
Short Circuit
Protection
Main Output & 5Vsb: Cycling type, auto recovery.
Fan Output: recovery only after removal of short and
load. See note 5 on page 1.
Power Factor
>0.99 @ 115Vac, Full Load
>0.95 @ 230Vac, Full Load
Overvoltage
Protection
OVP latch, see chart for trip ranges.
5V standby output (latch), see chart for trip range.
Efficiency
See Model Selection Chart on page 1.
Switching Frequency
75kHz, typical
Output Power
425W continuous, with 200 lfm airflow
300W convection cooled – See chart for specific
voltage model ratings.
Isolation
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vdc
Transient Response
50% load step, i/t: <0.2A/μS. Max Voltage
Deviation = 5%. Recover to within 1% of nominal
within 500µS
Operating
Temperature
-
10 to 70°C
. Starts
up
at
-
40°C
. The unit will meet
all published specifications after a warm-up period.
See Application Note for operating conditions during
start-up.
Ripple and Noise
0.5%rms, 1% pk-pk, see Model Selection Chart on
page 1.
Temperature
Derating
Derate output power linearly above 50°C to 50% at
70°C
Common Mode
Noise
Line Frequency
: <2.5V
rms
@115Vac, <5V
rms
@
230Vac, 50/60Hz. See App Note for test
set-up and typical graphs. For high frequency
noise, consult the factory.
Storage
Temperature
-40°C to +85°C
Output Voltage
See chart on page 1. Initial setpoint within 0.5%
of nominal. Adjustable +/-5% from nominal
(except 56V)
Altitude
Operating: up to 5000m (derating may be required
above 3000m, consult factory)
Non-operating: -500 to 40,000 ft.
Minimum Load
Not req
uired for main output or 5Vsb.
Fan Output: 0.5A min required on the main
output in order for the 12V Fan output to be
within regulation.
Relative Humidity
5% to 95%, non-condensing
Total Regulation
See Model Selection Chart on page 1.
Shock
Operating: Half
-
sine, 20gpk, 10ms, 3 axes, 6 shocks
total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6
shocks total
Vibration
Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10
min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall, 3
axes, 1 hr/axis
Safety Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition
Dimensions
W: 3.3” x L: 6.2” x H: 1.62”
W: 84mm x L: 157.5mm x H: 41mm
MTBF
See Model Selection Chart on page 1.
Weight
670g
E-Cap Life
7 years, based on typical operation of 12 hours/day,
261 days/year at 40°C ambient temp.
TU425
425W Single Output
Test and Measurement/Industrial Series
www.slpower.com TU425 REV 2.8 29-MAY-15 3
Auxiliary Signals
DC OK:
Goes
HIGH
when main DC output is above 90%
of nominal voltage and goes LOW when the
output is below 90% of rated main output DC
voltage
Power Good/ Power
Fail:
Signal is high within 500mS after the main output is
within regulation band upon AC turn on. Goes low
with 4 mS min. before the main DC output drops
below 90% of nominal value when AC turns off.
Inhibit:
Logic HIGH or open = ON
Logic LOW or short to ground = OFF
Fan Output:
12V @ 1 A (air cooled ) or 0.5A (convection),
+/-10% regulation for load change of 0.5A to FL on the
main output.
Remote Sense:
Compensates for up to 0.5V voltage drop
for 48V & 56V models, and 0.16V voltage drop
for 12V & 24V models. Maximum deviation of
5% (main output) any 50% step above 5% load.
Current Share¹:
Active single wire, up to
4 supplies in parallel. Paralleled
output voltages must be set to within 0.5% of each
other. Contact Factory for details on the required set-up
for proper operation.
5V Standby Output:
5V @ 2A, +/-
5% regulation over all
changes in main output load current.
Current Share
Accuracy¹:
5% when the load current is
50% of the total
available load current, 10% when the load current is
between 25% - 49% of the total available load current.
Remote sense lines must be connected to ensure
accuracy.
Notes: 1. Consult Factory for proper set-up for current sharing operation.
EMI/EMC Compliance
Conducted Emissions
EN55011/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, typical.
Radiated Emissions
EN55011/CISPR22 Class A, FCC Part 15.109, Class A, 3db margin, typical.
Static Discharge Immunity
EN55024/IEC61000-4-2, Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A
Radiated RF Immunity
EN55022/IEC61000-4-3, Level 2, 3V/m, Criteria A
EFT/Burst Immunity
EN55024/IEC61000-4-4, Level 3, 2kV (PS Output), 1kV (signal outputs), Criteria A
Line Surge Immunity
EN55024/IEC61000-4-5, Level 3, 1kV diff., 2kV common-mode, Criteria A
Level 4, 2kV diff., 4kV Common-mode, Criteria C
Conducted RF Immunity
EN55022/IEC61000-4-6, Level 3, 10V/m, Criteria A
Power Frequency Magnetic Field Immunity
EN55024/IEC61000-4-8, Level 3, 10A/m, Criteria A
Voltage Dip Immunity
EN55024/IEC61000-4-11, Dips: 100%, 10ms; 30%, 500ms; 60%, 100ms;
Interruptions: 100%, 5000mS; Performance Criteria A, A, B & B
Line Harmonic Emissions
EN55024/IEC61000-3-2, Class A, C & D at full load (425W output).
Flicker Test
EN55024/IEC61000-3-3, Section 5
Connector Information
Input Connector
J101
Main DC Output
J302, J303
Fan Output
J301
Signal Connector
J401
PIN 1) FG
PIN 2) NC
PIN 3) AC Neutral
PIN 4) NC
PIN 5) AC Line
Term 1
J302: (+V)
Term 2 – J303: (─V)
PIN 1) 12V Fan (+)
PIN 2) 12V Fan (─)
PIN 1) Remote Sense (+)
Pin 6) Power Good
PIN 2) Common Pin 7) +5Vsb Output
PIN 3) Remote Sense (─) Pin 8) +5Vsb Output
PIN 4) Current Sharing Pin 9) DC OK
PIN 5) Remote Inhibit Pin 10) Common
Mating Connector:
Tyco/AMP 640250-5
Pins: 3-770476-1
Mating Connector:
Molex 19141-0058
19141-0063
19141-0083
Mating Connector:
Tyco AMP 1375820-2
Pins: 1375819-1
Mating Connector:
Molex 90142-0010
Pins: 90119-2110