1
Suppression Chokes
DKLP-1
www.schurter.com /PG81_82
EMC Products
Compensated High Inductance Choke, 1-phase
Description
- Current compensated choke
- 1-phase choke
- Flexible wire
- Flange for mounting onto printed circuit board
- Fully potted resign
Standards
- EN 60938
- UL 1283
- CSA 22.2 no 8
Applications
- Placed in front of frequency converter
- Stepper motor drives
- UPS-systems
- Inverter
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Detailed request for product
Technical Data
Rated voltage up to 540 VAC
␣ up to 760 VDC
Rated Current 4 - 20 A @ Ta 40 °C
Rated inductance 14 - 60 mH, Tol. -30% +50%
Power Operating Frequency 50 - 400 Hz
Terminal Type Flexible wire
Weight 145 - 512 g
Material: Housing UL 94V-0
Sealing Compound UL 94V-0
Test Voltage 2.5 kV, 50 Hz, 2 sec, winding to winding
Isolation Voltage 2.5 kV eff., 50 Hz, 2 sec, winding to
ambient
Climatic Category 25/100/21 acc. to IEC 60068-1
Allowable Operation Temp. -25 °C to 100 °C
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
General Product Information
Dimension
Case 29-2W
48
38.2
3.1
48
5.8
38.2
30.8
150
10...20
Case 31-2W
80
65
4.3
80
6.8
65
50.8
230
10...20