TL1L3-LW1,L
12
11.
11.
11.
11. Cleaning
Cleaning
Cleaning
Cleaning
Flux cleaning should be completed free of residual reactive ion such as Na, Cl, etc. Organic solvent acts upon
water and generates corrosive gas such as hydrogen chloride. There are some cases where the device
is degraded.
Effective solvent seriously affects package and resin, and may cause inferior device. In actually using it, please
sufficiently check whether there is nothing inferior on the device.
Ultrasonic cleaning that provides effective cleaning for short time much affects on the device. so coherence
between resin and lead metal is degraded by cleaning solvent during long ultrasonic cleaning. We recommend
to take ultrasonic cleaning for the device at a minimum range. The influences on a device is occurred by
the output of an ultrasonic wave and set board, please sufficiently check whether there is nothing inferior
on the device.
12.
12.
12.
12. Tape Specifications
Tape Specifications
Tape Specifications
Tape Specifications
12.1.
12.1.
12.1.
12.1. Product Naming Conventions
Product Naming Conventions
Product Naming Conventions
Product Naming Conventions
The type of package used for shipment is denoted by a symbol suffix after the part number. The method of
classification is as below. (this method, however does not apply to products whose electrical characteristics differ
from standard Toshiba specifications)
Example: TL1L3-LW1,L
Toshiba part number: TL1L3-LW1
Packing type: L (Taping)
12.2.
12.2.
12.2.
12.2. Handling Precautions
Handling Precautions
Handling Precautions
Handling Precautions
(1) The tape is antistatic-coated. However, if the tape is charged with excess static electricity, devices might
cling to the tape or waggle in the tape when the cover tape peeled off. Be aware of the following to avoid
this:
Use an ionizer to neutralize the ions when utilizing an automatic mounter.
For transport and temporary storage of devices, use containers (boxes, jigs, bags) that are made with
antistatic materials or materials that dissipate static electricity.
12.3.
12.3.
12.3.
12.3. Tape Dimensions
Tape Dimensions
Tape Dimensions
Tape Dimensions
Table
Table
Table
Table 12.3.1
12.3.1
12.3.1
12.3.1 Tape Dimensions (Unit: mm)
Tape Dimensions (Unit: mm)
Tape Dimensions (Unit: mm)
Tape Dimensions (Unit: mm)
Dimensions
Tolerance
D
1.5
+0.1/-0
E
1.75
±0.1
P
0
4.0
±0.1
t
0.3
±0.05
F
5.5
±0.05
D
1
1.7
±0.1
P
2
2.0
±0.05
W
12.0
±0.2
P
8.0
±0.1
A
0
3.8
±0.1
B
0
3.8
±0.1
K
0
2.65
±0.1
2014-09-04
Rev.2.0