PDU3VSR6G30

10kW 3-Phase Switched PDU, 200/208/240V
Outlets (24-C13, 6-C19), IEC-309 30A Blue, 6ft
Cord, 0U Vertical, TAA
MODEL NUMBER: PDU3VSR6G30
Description
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and
monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle,
monitor site electrical conditions and remotely monitor output power consumption per-phase or per-
receptacle. PowerAlert interface supports remote control and custom notification of user-specified
conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be
controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for
user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems
and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be
electronically locked off to prevent the connection of unauthorized hardware. Built-in local digital display
and remote web/network interface reports detailed voltage, amperage and kilowatt output values per
outlet, per breaker bank and per phase with additional reporting options for power unbalance percentage,
IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor).
Features
10kW 3 phase 200/208/240V Switched Power Distribution Unit / PDU with built-in web/network interface
and multi-function digital display
Attached IEC-309 Blue 30A (3P+E) 200/208/240V 3 phase input; 6 ft. / 1.8m cord
0U, 70 inch / 178cm vertical form factor
30 switched 200/208/240V outlets (24 C13, 6 C19) arranged in 3 separately breakered single phase
load banks
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional
loads and disabling unused outlets
Highlights
Switched 10kW 3 Phase
200/208/240V PDU; 70 in. /
178cm 0U vertical rackmount
Reports voltage and load per-
outlet or per-phase via ethernet
interface
1% billing-grade accuracy, Multi-
function digital display,
Environmental monitoring
options
70in / 1778mm 0U vertical
format; Toolless button-mount
installation
24 C13 & 6 C19 single phase
switched outlets; Plug-lock cable
retention sleeves
IEC-309 Blue 30A (3P+E)
200/208/240V 3 phase input; 6
ft. / 1.8m line cord
TAA Compliant
Package Includes
Switched vertical rackmount
PDU with pre-installed mounting
buttons
Plug lock cord retention sleeves
Spare installation buttons (2
9mm / 4 6mm), Mounting
brackets
Configuration cable
Owner's manual
1 / 4
Specifications
Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load
levels with +/-1% billing-grade accuracy
Built-in digital display and remote web/network interface reports detailed voltage, amperage and kilowatt
output values per outlet, per breaker and per phase with additional reporting options for power
unbalance percentage, IP address and sensor based temperature and humidity data (requires
ENVIROSENSE sensor)
Supports user-specified alarm notification thresholds
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack
access notification with up to 4 optional SRSWITCH or user-supplied contact closure sensors
DHCP/Manual configuration support
10/100 Mbps auto-sensing
Real-time clock backup maintains the time of day and date even if the PDU is unpowered
Tiered access privileges allow an administrator and a guest to login via web browser
Alert notifications via email or SNMP traps offer immediate event notification
Firmware upgrade ability supports future product enhancements
Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2,
SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
Fully compatible with FREE PowerAlert Network Management System / NMS Software
Included set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outlets
Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for
other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons
included)
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
OVERVIEW
UPC Code 037332180230
PDU Type Switched
OUTPUT
Output Capacity Details 10kW (240V), 9.6kW (230V), 9.1kW (220V), 8.6kW (208V), 8.3kW (200V) total capacity; 13.9A max per breakered
outlet bank; 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (24) C13; (6) C19
Output Nominal Voltage 200; 208; 240
Overload Protection 3 20A circuit breakers, one per output load bank
2 / 4
Customized Load Management
Receptacles
Each outlet is individually controllable via remote interface
INPUT
PDU Input Voltage 200; 208; 240
Recommended Electrical Service 30A 208/240V with IEC309 30A Blue (3P+E) outlet
Maximum Input Amps 24
PDU Plug Type IEC-309 30A BLUE (3P+E)
Input Cord Length (ft.) 6
Input Cord Length (m) 1.83
Input Phase 3-Phase
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments Reports input current per phase (L1, L2, L3), plus output current for each output load bank (13.9A balanced max per
banks B1-B3) and individual output receptacle (1-30); Outlets are color-coded and labeled for phase and load bank
identification; L1-L2 feeds black outlets (B1); L2-L3 feeds dark-gray outlets (B2); L3-L1 feeds light-gray outlets (B3)
Front Panel LCD Display Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity*
information (*requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large
display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Outlet (##), Load unbalance % (UB), Output
power (OP)
Front Panel LEDs Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V),
Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output receptacle
offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load
bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip)
Switches Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options;
Additional MODE button advances the LEDs to view the next measurement
PHYSICAL
Shipping Dimensions (hwd / in.) 75.870 x 9.650 x 6.890
Shipping Dimensions (hwd / cm) 192.71 x 24.51 x 17.50
Shipping Weight (lbs.) 23.6200
Shipping Weight (kg) 10.71
Unit Dimensions (hwd / in.) 70 x 2.17 x 2.86
Unit Dimensions (hwd / cm) 177.8 x 5.5 x 7.3
Unit Weight (lbs.) 16.55
Unit Weight (kg) 7.51
Material of Construction Metal
Form Factors Supported Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-
mount compatible racks
PDU Form Factor Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range 32 to 122F (0 to 50C)
3 / 4

PDU3VSR6G30

Mfr. #:
Manufacturer:
Tripp Lite
Description:
Power Outlet Strips PDU 3-Phase Switched 208V 8.6 kW IEC-309 24 C13; 6 C19 0URM TAA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS