CBI2420A
DC UPS
The Altech DC-UPS system is built to optimize power
management. The available power is automatically allocated
between load and battery, supplying power to the load is the first
priority. For high inrush applications the charging power will
reroute automatically to the load. In this case the maximum
available current on the load output is two times the value of the
device rated current.
The Battery Care concept based on algorithms that achieve rapid
a
nd automatic charging, battery optimization during charging
time, flat batteries recovery and real time diagnostic The Real
Time Auto-diagnostic system, monitors battery faults, sulfated
battery, short circuit battery elements, reverse polarity
connection, battery disconnect. This conditions are detected and
identified by the number of blinks of the diagnosis Led.
The Altech DC-UPS system is designed to charge and monitor all
battery types, by selecting the battery type via jumpers. The
predefined curves include Open Lead Acid, Sealed Lead Acid, Gel,
Ni-Cd (optional) battery types. The charging curve are
programmed to automatically switch between Recovery Charge,
Boost charge and Trickle charge. The continuous battery efficiency
monitoring, reduces battery damage risk and allows a safe
operation in permanent connection.
A compact and rugged metal case with DIN rail mounting bracket
provide an easy installation and an IP20 protection.
Voltage
Current
Fast / Boost ChargeRecovery Charge Tickle / Float Charge
Voltage / Current
In Vac
Battery
Mains or Backup
Load
Out 1
CBI
Battery Low or
Start From Battery
Battery Replacement
Out 2
Jumper for Battery Type Selection
Jumper for Functional Setting
MAINS
OR
BACKUP
LOW BATTERY
OR BATTERY
REPLACEMENT
DIAGNOSIS
NL
5678910
Open
Lead
Sealed
Lead Low
Sealed
Lead High
Gel
Battery
Gel
Battery (1)
NiCd -
NiMh (1)
Battery Life
Test On
1
1
J
umper present: life test enabled.
2
Jumper present: fast test enabled.
3
Jumper present: fast recovery charge
enabled only for size 3. Possibility to
recharge the battery also when the
voltage is close to zero with the
maximum power of the device.
Fast Charge
Enable
2
Fast Recovery
Charge (2)
3
–
+–+
(3) (4)
–
+–+
(
1) (2)
MAINS
OR
BACKUP
LOW BATTERY
OR BATTERY
REPLACEMENT
12345 6 7
12345 6 7
1
2345 6 7
12345 6 7
12345 6 7
1
2345 6 7
12345 6 7
12345 6 7
12345 6 7
TIME
BUFFERING
OUTPUT LOAD
BATTERY
BATTERY
START
Signal Output Contacts
Main or Backup Power Yes
Battery Power Low Yes
Battery Fault Yes
Max. Current Rating (Resistive Load) 1A 30 VDC/60 VAC
Minimum Permissible Current Rating 1mA @ 5 VDC
RJ45 Connection Input/Output
Temp. Comp. Battery (with ext. probe) Yes - Optional
Remote monitoring display Yes - Optional
Can Bus No
Environment
Insulation voltage (IN/OUT) 3000 VAC
Insulation voltage (input / ground) 1605 VAC
Insulation voltage (Output / ground) 500 VAC
Protection Class (EN/IEC 60529) IP20
Pollution Degree Environment 2
Connection TB, Screw Terminal 4 mm² (30-10 AWG)
Protection class (Ground Connected) Class I
Dimensions (WxHxD) 150x115x135 mm
5.91x4.53x5.32 in
Weight (approx.) 1.55 kg (3.5 Lbs)
Safety and EMC
Battery charger standard compliance IEC/EN 60335-2-29
Safety standards compliance: EN60950 / UL1950 / CE
Fire Detection and alarm compliance EN54-4
EMC Directive 89/336/EEC
Charging cycle DIN41773
Emission IEC 61000-6-4
Immunity IEC 61000-6-2