TLE 4284
Data Sheet 9 Rev. 2.1, 2007-03-20
Dropout voltage V
DR
– 1.00 1.20 V I
Q
=100 mA
3)
– 1.05 1.30 V I
Q
=500 mA
3)
– 1.10 1.35 V I
Q
=800 mA
3)
– 1.30 1.40 V I
Q
=1.0A
3)
Current consumption
I
q
= I
I
– I
Q
I
q
–0.81.6mAI
Q
=10mA
Temperature stability – – 11 – mV
4)
Current limit I
Qmax
1000 – 2200 mA V
I
– V
Q
< 18V;
V
Q
= V
nom
- 100 mV
50 200 – mA
V
I
= 40 V;
V
Q
= V
nom
- 100 mV
T
j
= 25 °C
RMS Output Noise – – 30 – ppm ppm of
V
Q
, T
j
= 25 °C
10 Hz ≤
f ≤ 10 kHz
4)
Power Supply Ripple
Rejection
PSRR
–65–dB f
r
= 120 Hz; V
r
= 0.5 V
PP
C
ADJ
= 0 µF
4)
–65–dBf
r
= 120 Hz; V
r
=0.5 V
PP
,
C
ADJ
= 10 µF
4)
1) Device is usable within given range without destruction, but the accuracy of the output voltage can only be
guarantied in the range specified in the line above.
2) Measured at constant junction temperature
3) Dropout voltage measured when the output voltage has dropped 100 mV from the nominal value.
4) Not subject to production test - specified by design.
Table 8 Electrical Characteristics TLE 4284 DV26 (2.6 V fixed output voltage)
-40 °C<
T
j
<150°C; V
I
=13.5V, I
Q
= 10 mA; unless otherwise specified
Parameter Symbol Limit Values Unit Measuring Conditions
min. typ. max.
Output voltage
V
Q
2.52 2.60 2.68 V 10 mA ≤ I
Q
≤ 1000 mA;
4.0 V ≤
V
I
≤ 16 V
–2.60–V10 mA ≤
I
Q
≤ 1000 mA;
16 V ≤
V
I
≤ 40 V
1)
Table 7 Electrical Characteristics TLE 4284 DV18 (1.8 V fixed output voltage)
-40 °C<
T
j
<150°C; V
I
=13.5V, I
Q
= 10 mA; unless otherwise specified
Parameter Symbol Limit Values Unit Measuring Conditions
min. typ. max.