TYPICAL CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
Fig. 5 - Forward Voltage vs. Forward Current Fig. 6 - Collector Current vs. Collector Emitter Voltage
SAFETY AND INSULATION RATINGS
PARAMETER SYMBOL VALUE UNIT
MAXIMUM SAFETY RATINGS
Output safety power P
SO
300 mW
Input safety current I
si
200 mA
Safety temperature T
S
150 °C
Comparative tracking index CTI 175
INSULATION RATED PARAMETERS
Maximum withstanding isolation voltage 40 % to 60 % RH, AC test of 1 min V
ISO
3750 V
RMS
Maximum transient isolation voltage V
IOTM
6000 V
peak
Maximum repetitive peak isolation voltage V
IORM
565 V
peak
Insulation resistance T
amb
= 25 °C, V
DC
= 500 V R
IO
≥ 10
12
Ω
Isolation resistance T
amb
= 100 °C, V
DC
= 500 V R
IO
≥ 10
11
Ω
Climatic classification (according to IEC 68 part 1) 55/110/21
Environment (pollution degree in accordance to DIN VDE 0109) 2
Creepage distance ≥ 5 mm
Clearance distance ≥ 5 mm
Insulation thickness DTI ≥ 0.4 mm
0.1
1
10
100
0.6 0.8 1.0 1.2 1.4 1.6
I
F
- Forward Current (mA)
V
F
- Forward Voltage (V)
T
amb
= 110 °C
T
amb
= 75 °C
T
amb
= 25 °C
T
amb
= 0 °C
T
amb
= - 55 °C
0
5
10
15
20
25
30
35
40
45
50
55
0 1 2 3 4 5 6 7 8 9 10
I
C
- Collector Current (mA)
I
F
= 30 mA
I
F
= 35 mA
I
F
= 1 mA
I
F
= 20 mA
I
F
= 15 mA
I
F
= 10 mA
I
F
= 5 mA
I
F
= 25 mA
V
CE
- Collector Emitter Voltage (V)