TMSB 2-108

http://www.tracopower.com Page 1 of 4
AC/DC Power Modules
TMSB 2 Series, 2 Watt
The TMSB-2 series are compact AC/DC power supplies in a fully encapsulated
plastic casing with solder pins for direct PCB mounting. They feature regulated
outputs and constant power characteristics which make them suitable to drive relays,
solenoids, LED’s and capacitive loads. Models with an additional regulated
auxiliary output can be used to power a logic circuit in standby functions.
An universal input voltage 85–264 VAC, safety approvals including approvals for
household applications (EN 60335-1) and an operating temp. range from –30°C to
+70°C qualify them for worldwide markets.
Features
Standby power module to comply
with ErP directive
No load input power < 150mW
Constant power characteristics at 2W
(no current limitation)
Suitable to drive relays, selenoids,
capacitive loads and LED’s
Constant voltage auxiliary outputs
3.3 and 5 VDC
Operating temperature range
–30°C to +70°C
EMI meets EN 55022, class B and
FCC, level B
Short circuit and overload protection
3-year product warranty
Order code Output power max. Output 1 Output 2 Efficiency
TMSB 2-108
2 W
8.0 VDC / 250 mA 72 %
TMSB 2-114
14 VDC / 143 mA 74 %
TMSB 2-124
24 VDC / 83 mA 76 %
TMSB 2-283
8.0 VDC / 250 mA
1)
3.3 VDC / 160 mA
1)
69 %
TMSB 2-285
8.0 VDC / 250 mA
1)
5.0 VDC / 250 mA
1)
69 %
TMSB 2-2143
14 VDC / 143 mA
2)
3.3 VDC / 70 mA
2)
70 %
TMSB 2-2145
14 VDC / 143mA
2)
5.0 VDC / 83 mA
2)
70 %
Models
LVD
C B
Scheme
UL 60950-1
1)
Iout1 + Iout2 = 250 mA max.
2)
Iout1 + Iout2 = 143 mA max.
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Modules
TMSB 2 Series 2 Watt
Input Specifications
Input voltage ranges – AC input 85 – 264 VAC
– DC Input 120 – 370 VDC
Input frequency 47 – 440 Hz
Input current at full load 41 mA typ.
No-Load power consumption <150 mW
External fuse (required) 3.15 A slow blow type (recommendation)
Input surge voltage 305 VAC max.
Output Specifications
Voltage set accuracy Output 1: ±5 % max.
Output 2: ±2 % max.
Minimum load no minimum load required
Ripple and noise (20 MHz bandwidth) Output 1: 1 Vp-p typ.
Output 2: 0.1 Vp-p typ.
Regulation – Input variation Output 1: 1 % typ.
Output 2: 0.3 % typ.
Regulation – Load variation (10 100%) Output 1: 1 % typ.
Output 2: 0.5 % typ.
Short circuit protection continuous, automatic recovery
General Specifications
Temperature ranges – Operating –30°C to +70°C
– Power derating 2.0 %/K above +60°C
– Storage (non operating) –40°C to +85°C
Temperature coefficient 0.02 %/°C
Humidity (non condensing) 95 % rel max.
Switching frequency (pulse width modulation PWM) 45 kHz typ.
Isolation voltage – Input/Output 4‘242 VAC
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >500000 h
Electromagnetic compatibility Conducted input RI suppression: EN 55022, class B, FCC part 15, level B
(EMC), emissions Radiated input suppression: EN 55014-1
Electromagnets compatibility – Electrostatic discharge ESD IEC / EN 61000-4-2, criteria A
(EMC), immunity – RF field immunity IEC / EN 61000-4-3, criteria A
– Electrical fast transients/burst immunity IEC / EN 61000-4-4, criteria A
– Surge IEC / EN 61000-4-5, criteria A
– Conducted RF IEC / EN 61000-4-6, criteria A
– Voltage dip IEC / EN 61000-4-11
Protection class II Acording IEC/EN 60536
Safety standards IEC/EN 60950-1 (ed. 2) AM 1, UL 60950-1,
CSA C22.2 No. 60950-1-07
EN 60335-1:2010
– Certification documents www.tracopower.com/overview/tmsb2
Casing material plastic resin + fiberglass (UL 94V-0 rated)
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
http://www.tracopower.com Page 3 of 4
AC/DC Power Modules
TMSB 2 Series 2 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Voltage (VDC)
Output Current (mA)
200 800700300 600 9001000 400 500
4
10
6
8
2
0
constant voltage
constant power area
Single output models:
Dual output models:
Output characteristics
(e.g. TMSB 2-108)
(e.g. TMSB 2-285)
0
1
2
3
4
5
6
7
8
9
TMSB 2-285
Vout [VDC]
Iout1 for Iout2 = 0 mA
Iout1 for Iout2 = 50 mA
Iout1 for Iout2 = 100 mA
0 100 200 300 400 500 600 700 800
0 100 200 300 400 500 600 700 800
0 100 200 300 400 500 600 700 800
Iout1 for Iout2 = 200 mA
0 100 200 300 400 500 600 700
Iout1 for Iout2 = 250 mA
0 100 200 300 400 500 600
700
Iout 1
[mA]
Vout 1
Vout 2

TMSB 2-108

Mfr. #:
Manufacturer:
TRACO Power
Description:
Switching Power Supplies
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union