ADuM240D/ADuM240E/ADuM241D/ADuM241E/ADuM242D/ADuM242E Data Sheet
Rev. A | Page 12 of 26
REGULATORY INFORMATION
See Table 17, Table 18, and the Insulation Lifetime section for details regarding recommended maximum working voltages for specific
cross-isolation waveforms and insulation levels.
Table 12. RW-16 Wide Body [SOIC_W] Package
UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under UL 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
2
Certified by
CQC11-471543-2012,
GB4943.1-2011:
Single Protection, 5000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and IEC 60950-1,
second edition, +A1+A2:
Reinforced insulation, V
IORM
=
849 peak, V
IOSM
= 8000 V peak
Basic insulation at
780 V rms (1103 V peak)
Double Protection, 5000 V rms
Isolation Voltage
Basic insulation at 780 V rms (1103 V peak) Basic insulation, V
IORM
= 849 V peak,
V
IOSM
= 12 kV peak
Reinforced insulation at
389 V rms (552 V peak),
tropical climate, altitude
≤5000 meters
Reinforced insulation at 390 V rms
(552 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient protection
(1 MOPP)), 490 V rms (686 V peak)
Reinforced insulation (2 MOPP), 238 V rms
(325 V peak)
CSA 61010-1-12 and IEC 61010-1 third edition:
Basic insulation at 300 V rms mains, 780 V
secondary (1103 V peak)
Reinforced insulation at 300 V rms mains,
390 V secondary (552 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each product is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥ 1592 V peak for 1 sec (partial discharge detection limit =
5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Table 13. RI-16 -2 Wide Body Increased Creepage [SOIC_IC] Package
UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
2
Certified by
CQC11-471543-2012,
GB4943.1-2011
Single Protection, 5000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and IEC 60950-1,
second edition, +A1+A2:
Reinforced insulation, V
IORM
=
849 peak, V
IOSM
= 8000 V peak
Basic insulation at
830 V rms (1174 V peak)
Double Protection, 5000 V rms
Isolation Voltage
Basic insulation at 830 V rms (1174 V peak) Basic insulation, V
IORM
= 849 V peak,
V
IOSM
= 12 kV peak
Reinforced insulation at
415 V rms (587 V peak),
tropical climate, altitude
≤5000 meters
Reinforced insulation at 415 V rms (587 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient protection
(1 MOPP)), 519 V rms (734 V peak)
Reinforced insulation (2 MOPP), 261 V rms
(369 V peak)
CSA 61010-1-12 and IEC 61010-1 third edition:
Basic insulation at 300 V rms mains, 830 V
secondary (1174 V peak)
Reinforced insulation at 300 V rms Mains,
390 V secondary (587 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM230D/ADuM230E/ADuM231D/ADuM231E is proof tested by applying an insulation test voltage ≥ 1018 V peak for
1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.