44 Lineage Power
Data Sheet
April 2008
4.5 Vdc to 14 Vdc Input; 5 W
MH005-Series Power Modules:
Electrical Specifications (continued)
Table 2. Output Specifications (continued)
* At less than the minimum current, units will continue to operate; however, the single-output modules (MH005A, B, C) may exceed their output
ripple specification. The dual-output modules (MH005BK, CL) may exceed their output voltage regulation limits if the output currents are
severely imbalanced with one output sourcing less than the minimum current.
† Output not in current limit is held at minimum load to give the worst-case (highest current level) inception point.
Parameter Device Symbol Min Typ Max Unit
Output Current-limit Inception
(See Figures 4—9.):
V
O = 4.5 V (~0.9 VO, set)
V
O = 10.8 V (~0.9 VO, set)
V
O = 13.5 V (~0.9 VO, set)
V
O1 or VO2 = 10.2 V
†
VO1 or VO2 = 12.75 V
†
MH005A
MH005B
MH005C
MH005BK
MH005CL
I
O
IO
IO
IO
IO
—
—
—
—
—
1.5
0.7
0.6
0.7
0.6
2.5
1.0
0.9
1.2
1.1
A
A
A
A
A
Output Current Limit
(V
I = 5 V, TA = 25 °C; See Figures
4—9.):
V
O = 1.0 V (~0.2 VO, set)
V
O = 1.0 V (~0.08 VO, set)
V
O = 1.0 V (~0.07 VO, set)
V
O1 or VO2 = 1.0 V
V
O1 or VO2 = 1.0 V
MH005A
MH005B
MH005C
MH005BK
MH005CL
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.5
2.5
2.5
2.5
2.5
A
A
A
A
A
Output Short-circuit Current
(V
O = 250 mV; see Figures 4—9.)
MH005A
MH005B
MH005C
MH005BK
MH005CL
—
—
—
—
—
—
—
—
—
—
3.0
1.4
1.4
1.3
1.3
—
—
—
—
—
A
A
A
A
A
Efficiency
(V
I = 5 V; IO = IO, max; TA = 25 °C;
see Figures 10, 11, 17, and 18.)
MH005A
MH005B
MH005C
MH005BK
MH005CL
η
η
η
η
η
70
70
70
70
70
72
73
73
73
73
—
—
—
—
—
%
%
%
%
%
Switching Frequency All — — 400 — kHz
Dynamic Response
(ýI
O/ýt = 1 A/10 µs, VI = 5 V,
T
A = 25 °C; see Figures 12 and 13.):
Load Change from I
O = 50% to 75%
of I
O, max:
Peak Deviation
Settling Time
(V
O < 10% peak deviation)
Load Change from I
O = 50% to 25%
of I
O, max:
Peak Deviation
Settling Time
(V
O < 10% of peak deviation)
All
All
All
All
—
—
—
—
—
—
—
—
60
4
60
4
—
—
—
—
mV
ms
mV
ms