44 Lineage Power
Data Sheet
April 2008
4.5 Vdc to 14 Vdc Input; 5 W
MH005-Series Power Modules:
Electrical Specifications (continued)
Table 2. Output Specifications (continued)
* At less than the minimum current, units will continue to operate; however, the single-output modules (MH005A, B, C) may exceed their output
ripple specification. The dual-output modules (MH005BK, CL) may exceed their output voltage regulation limits if the output currents are
severely imbalanced with one output sourcing less than the minimum current.
Output not in current limit is held at minimum load to give the worst-case (highest current level) inception point.
Parameter Device Symbol Min Typ Max Unit
Output Current-limit Inception
(See Figures 4—9.):
V
O = 4.5 V (~0.9 VO, set)
V
O = 10.8 V (~0.9 VO, set)
V
O = 13.5 V (~0.9 VO, set)
V
O1 or VO2 = 10.2 V
VO1 or VO2 = 12.75 V
MH005A
MH005B
MH005C
MH005BK
MH005CL
I
O
IO
IO
IO
IO
1.5
0.7
0.6
0.7
0.6
2.5
1.0
0.9
1.2
1.1
A
A
A
A
A
Output Current Limit
(V
I = 5 V, TA = 25 °C; See Figures
4—9.):
V
O = 1.0 V (~0.2 VO, set)
V
O = 1.0 V (~0.08 VO, set)
V
O = 1.0 V (~0.07 VO, set)
V
O1 or VO2 = 1.0 V
V
O1 or VO2 = 1.0 V
MH005A
MH005B
MH005C
MH005BK
MH005CL
3.5
2.5
2.5
2.5
2.5
A
A
A
A
A
Output Short-circuit Current
(V
O = 250 mV; see Figures 4—9.)
MH005A
MH005B
MH005C
MH005BK
MH005CL
3.0
1.4
1.4
1.3
1.3
A
A
A
A
A
Efficiency
(V
I = 5 V; IO = IO, max; TA = 25 °C;
see Figures 10, 11, 17, and 18.)
MH005A
MH005B
MH005C
MH005BK
MH005CL
η
η
η
η
η
70
70
70
70
70
72
73
73
73
73
%
%
%
%
%
Switching Frequency All 400 kHz
Dynamic Response
(ýI
O/ýt = 1 A/10 µs, VI = 5 V,
T
A = 25 °C; see Figures 12 and 13.):
Load Change from I
O = 50% to 75%
of I
O, max:
Peak Deviation
Settling Time
(V
O < 10% peak deviation)
Load Change from I
O = 50% to 25%
of I
O, max:
Peak Deviation
Settling Time
(V
O < 10% of peak deviation)
All
All
All
All
60
4
60
4
mV
ms
mV
ms
Lineage Power 5
Data Sheet
April 2008
4.5 Vdc to 14 Vdc Input; 5 W
MH005-Series Power Modules:
Electrical Specifications (continued)
Table 3. Isolation Specifications
General Specifications
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions and Design Considerations for further information.
Parameter Min Typ Max Unit
Isolation Capacitance 1200 pF
Isolation Resistance 10
Parameter Min Typ Max Unit
Calculated MTBF (I
O = 80% of IO, max; TC = 40 °C) 5,000,000 hours
Weight 113 (4.0) g (oz.)
Parameter Device Symbol Min Typ Max Unit
Output Overvoltage Protection (clamp) MH005A
MH005B
MH005C
MH005BK
MH005CL
V
O, clamp
VO, clamp
VO, clamp
VO1, clamp
VO2, clamp
VO1, clamp
VO2, clamp
7.0
17
19
17
–17
19
–19
V
V
V
V
V
V
V
6 Lineage Power
MH005-Series Power Modules: Data Sheet
4.5 Vdc to 14 Vdc Input; 5 W April 2008
Characteristic Curves
8-927(C)
Figure 1. MH005-Series Typical Input
Characteristics with I
O = IO, max and
T
A = 25 °C
8-928(C)
Figure 2. MH005-Series Typical Output Voltage
Variation over Operating Case
Temperature
8-871(C).a
Figure 3. MH005BK, CL Typical VO vs. IO
Regulation with V
I = 5 V and TA = 25 °C
8-929(C)
Figure 4. MH005A, B, C Typical Output
Characteristics with V
I = 5 V and
T
A = 25 °C
02 4 6810121416
0
0.5
1.0
1.5
2.0
2.5
INPUT VOLTAGE, V
I
(V)
INPUT CURRENT, I
I
(A)
-100 102030405060 100
0.95
0.98
0.99
1.00
1.01
1.02
1.03
1.04
1.05
CASE TEMPERATURE, T
C (˚C)
VO /VO , set, nom
0.97
0.96
70 80 90
VO = 1.02 VO , nom
VO = VO , nom
VO = 0.98 VO , nom
0.04 0.08
0.12
0.16 0.20
OUTPUT CURRENT, I
O1 (A)
OUTPUT VOLTAGE, V O1 (V)
0.01
1.05 V
O, set
VO, set
0.95 VO, set
IO2 = 0.1 A
IO2 = 0.01 A
IO2 = 0.21 A
0 0.5 1.0 1.5 2.0 2.5 3.0 3.
5
0.00
0.20
0.40
0.60
0.80
1.00
OUTPUT CURRENT, I
O (A)
NORMALIZED OUTPUT VOLTAGE, V O /VO , se
t
MH005B
MH005C
MH005A

MH005A

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 5V 5W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union