November 2006 Rev 1 1/36
36
VIPer53 - E
OFF-line primary switch
Features
Switching frequency up to 300kHz
Current limitation
Current mode control with adjustable limitation
Soft start and shut-down control
Automatic burst mode in standby condition
(“Blue Angel“ compliant )
Undervoltage lockout with Hysteresis
HIgh voltage star-tup current source
Overtemperature protection
Overload and short-circuit control
Description
The VIPer53-E combines an enhanced current
mode PWM controller with a high voltage
MDMesh Power Mosfet in the same package.
Typical applications cover offline power supplies
with a secondary power capability ranging up to
30W in wide range input voltage, or 50W in single
European voltage range and DIP-8 package, with
the following benefits:
Overload and short circuit controlled by
feedback monitoring and delayed device reset.
Efficient standby mode by enhanced pulse
skipping.
Primary regulation or secondary loop failure
protection through high gain error amplifier.
General features
Type
European
(195 - 265Vac)
US / Wide range
(85 - 265 Vac)
DIP-8 50W 30W
PowerSO-10
TM
65W 40W
DIP-8PowerSO-10
www.st.com
Block diagram
FF
OSCILLAT OR
150/400ns
BLANKING
1V
4V
OVERTEMP.
DETECTOR
8.4/
11.5V
15V
0.5V
VDD
OSC DRAIN
TOVL COMP SOURCE
PWM
LATCH
ON/OFF
BLANKING TIME
SELECTION
PWM
COMPARATOR
CURRENT
AMPLIFIER
S
R1
R2
R3 R4 R5
Q
8V
4.35V
OVERLOAD
COMPARATO R
18V
4.5V
125k
0.5V
STANDBY
COMPARATO R
OVERVOLTAGE
COMPARATOR
ERROR
AMPLIFIER
UVLO
COMPARATOR
H
COMP
Contents VIPer53 - E
2/36
Contents
1 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Pin connections and function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Operation pictures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 Primary regulation configuration example . . . . . . . . . . . . . . . . . . . . . . 15
6 Secondary feedback configuration example . . . . . . . . . . . . . . . . . . . . 17
7 Current mode topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8 Standby mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9 High voltage Start-up current source . . . . . . . . . . . . . . . . . . . . . . . . . . 22
10 Short-circuit and overload protection . . . . . . . . . . . . . . . . . . . . . . . . . . 24
11 Transconductance error amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
12 Special recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
13 Software implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
14 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
15 Order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
16 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
VIPer53 - E Electrical data
3/36
1 Electrical data
1.1 Maximum rating
Stressing the device above the rating listed in the “Absolute Maximum Ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the Operating sections of
this specification is not implied. Exposure to Absolute Maximum Rating conditions for
extended periods may affect device reliability. Refer also to the STMicroelectronics SURE
Program and other relevant quality documents.
1.2 Thermal data
Table 1. Absolute maximum rating
Symbol Parameter Value Unit
V
DS
Continuous drain source voltage (T
J
= 25 ... 125°C)
(1)
-0.3 ... 620 V
I
D
Continuous drain current Internally limited A
V
DD
Supply voltage 0 ... 19 V
V
OSC
OSC input voltage range
0 ... V
DD
V
I
COMP
I
TOVL
COMP and TOVL input current range
(1)
1. In order to improve the ruggedness of the device versus eventual drain overvoltages, a resistance of 1k
should be inserted in series with the TOVL pin.\
-2 ... 2 mA
V
ESD
Electrostatic discharge:
Machine model (R = 0; C = 200pF)
Charged device model
200
1.5
V
kV
T
J
Junction operating temperature Internally limited °C
T
C
Case operating temperature -40 to 150 °C
T
STG
Storage temperature -55 to 150 °C
Table 2. Thermal data
Symbol Parameter
PowerSO-10
(1)
1. When mounted on a standard single-sided FR4 board with 50mm² of Cu (at least 35 mm thick) connected
to the DRAIN pin.
DIP-8
(2)
2. When mounted on a standard single-sided FR4 board with 50mm² of Cu (at least 35 mm thick) connected
to the device tab.
Unit
R
thJC
Thermal Resistance Junction-case Max 2 20 °C/W
R
thJA
Thermal Resistance Ambient-case Max 60 80 ° C/W

VIPER53DIP-E

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
AC/DC Converters 620 Volt 50W SMPS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union