HIH-4000-002

4 www.honeywell.com/sensing
Figure 3. Typical Output Voltage vs Relative Humidity (At 25 ºC and 5 V.)
TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (at 25 ºC and 5 V)
0.5
1
1.5
2
2.5
3
3.5
4
0 20 40 60 80 100
Relative Humidity (%RH)
Output Voltage (Vdc)
Sensor Response
Sensor Response
Best Linear Fit
Figure 4. Typical Output Voltage (BFSL) vs Relative Humidity (At 0 ºC, 70 ºC and 5 V.)
TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (at 0 ºC
and 70 ºC, 5 V)
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%)
Output Voltage (Vdc)
0 C
70 C
Honeywell Sensing and Control 5
Figure 5. Mounting Dimensions (For reference only. mm/[in])
12,7 MIN.
[0.50]
8,59
[0.338]
1,27
[0.050]
2,54
[0.100]
3X 0,38
[0.015]
4,17
[0.164]
4,17
[0.164]
2,54
[0.100]
12,2 MIN.
[0.48]
1,91
[0.075]
8,59
[0.338]
2,03
[0.080]
3X 0,38
[0.015]
HIH-4000-001
HIH-4000-003
HIH-4000-005
HIH-4000-002
HIH-4000-004
2,54
[0.100]
-ve +ve
OUT
-ve
+ve
OUT
0,89
[0.035]
Figure 6. Typical Application Circuit
HIH-40XX
+ Ve
- Ve
OUT
Supply Voltage (5 V)
VOLTAGE OUT
0 V
Minimum
Load
80
kOhm
ORDER GUIDE
Catalog Listing
Description
HIH-4000-001
Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP
HIH-4000-002
Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP
HIH-4000-003
Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP, calibration and data printout
HIH-4000-004
Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP, calibration and data printout
HIH-4000-005
Equivalent to HIH-4000-001
ADDITIONAL HUMIDITY SENSOR INFORMATION
See the following associated literature at www.honeywell.com/sensing:
Product installation instructions
Application sheets:
Humidity Sensor Performance Characteristics
Humidity Sensor Theory and Behavior
Humidity Sensor Moisture and Psychrometrics
Thermoset Polymer-based Capacitive Sensors
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
009017-5-EN IL50 GLO Printed in USA
February 2010
© 2010 Honeywell International Inc. All rights reserved.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax

HIH-4000-002

Mfr. #:
Manufacturer:
Description:
Board Mount Humidity Sensors HUMIDITY RANGE:0-100 lead pitch SIP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union