Input Voltage Range ±10% max.
Output Voltage Accuracy -1% typ., ±5% max.
Line Voltage Regulation (low line to high line at max. load) 1.2% typ.
Load Voltage Regulation (10% to 100% full load) 10% typ., 15% max.
Output Ripple and Noise (20MHz BW limited) 50mVp-p typ., 100mVp-p max.
Operating Frequency (Vin=nominal input) 20kHz min. / 40kHz typ. / 80kHz max.
Efficiency at Full Load see Selection Guide
Minimum Load = 0% Specifications valid for 10% minimum load only
Isolation Voltage (tested for 1 second) 2000 VDC
(rated for 1 minute**) 1600VDC
Isolation Voltage H-Suffix (tested for 1 second) 3000 VDC
H-Suffix (rated for 1 minute**) 2400VDC
Isolation Capacitance 30pF typ., 50pF max.
Isolation Resistance (Viso=500V) 15GΩ min.
Short-Circuit Protection 1 second
Operating Temperature Range with Derating -40°C to +90°C
Storage Temperature -55°C to +125°C
Reflow Temperature RoHS compliant 245°C (30 sec.), Peak 255°C (5sec.) max.
Vapor Phase Process (for more details see Application Notes) 230°C (90 sec.) max.
Relative Humidity 95% RH
Package Weight 1.4g
Packing Quantity All Types 27 pcs per Tube
All Types 500 pcs per Reel
MTBF (+25°C) using MIL-HDBK 217F 3907 x 10³ hours
MTBF (+85°C) using MIL-HDBK 217F 313 x 10³ hours
Certifications
EN Medical Safety Report: MDD1112018 + RM1112018 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
EN General Safety Report: SPCLVD1112018 EN60950-1, 2nd Edition
}
Detailed Information see
Application Notes chapter "MTBF"
Derating-Graph
(Ambient Temperature)
Selection Guide
Part Isolation Input Output Output Capacitive
Number Voltage Voltage Voltage Current Efficiency Load
SMD (kV) (VDC) (VDC) (mA) (max.) (max.)
(1)
RTM-0505S* 2 5 5 400 79% 2200µF
RTM-1205S* 2 12 5 400 83% 2200µF
RTM-2405S* 2 24 5 400 84% 2200µF
* add Suffix “/H“ for 3kVDC/1sec. Isolation e.g. RTM-0505S/H
* add Suffix “-R“ for tape&reel packing e.g. RTM-1205S-R or RTM-2405S/H-R
Specifications
(
measured at T
A
= 25°C, nominal input voltage and rated output current unless otherwise specified)
2 Watt SMD
Single Output
●
1:1 Input Range
●
Efficiency up to 84%
●
2kVDC and 3kVDC Isolation Option
●
Approved for Medical Applications
●
-40°C to +90°C Operating Temperature Range
●
2W SMD Package
Features
Unregulated
Converters
EN-60601-1 Certified
EN-60950-1 Certified
RTM
ECONOLINE
DC/DC-Converter
Refer to Application Notes
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Note:
Note1: Maximum capacitive load is defined as the capacitive load that will allow start up in under
1 second without damage to the converter
REV: 0/2015 E-83www.recom-power.com